Error Messages - Mx Onda MX-PI2624 Manual De Usuario E Instalacion

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ERROR MESSAGES

If an abnormality arises, the induction hob will enter the protection state
automatically and display the corresponding error codes:
Message
Protection against under voltage (<85
E 1 / E 2
V) or over voltage (> 285 V)
Induction coil temperature sensor
E 3
fault.
E 4
IGBT temperature sensor failure
High temperature (> 280 ºC) of the
E 5
induction coil temperature sensor.
E 6
High temperature at IGBT sensor
E r
Internal fault of the control circuits.
There is excess liquid on the buttons
r
on the control panel
INSTALLATION
Drill a hole in the worktop based on the following suggestions:
It must leave at least a minimum of 5 cm around the hole, free of obstacles
(furniture, appliances, etc.).
The thickness of the worktop is at least 30 mm.
Choose the material of the worktop that is heat resistant to avoid
deformation caused by heat radiation from the induction hob.
L(mm)
W(mm)
590
Description
H(mm)
520
55
If the voltage at the mains outlet is lower or
higher than specified, consult a qualified
electrician.
Contact the closest MX ONDA Official
Technical Service.
Contact the closest MX ONDA Official
Technical Service.
Turn off the induction hob and wait for it to
cool down.
Check that the ventilation is correct and the
fans are not obstructed.
Contact the closest MX ONDA Official
Technical Service.
Clean and dry the control panel
D(mm)
A(mm)
51
560
17
Solution
B(mm)
X(mm)
490
50 min.