Maintenance; Troubleshooting; Technical Data - Urrea EA1004 Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MAINTENANCE

WARNING: Before cleaning or performing
any maintenance, the tool should be un-
plugged from the power supply. Using com-
pressed air may be the most effective cleaning
method. Always wear safety goggles when
cleaning tools using compressed air.
WARNING: Do not let brake fluid, gasoline,
petroleum-based products, penetrating oil,
etc., come into contact with plastic parts. These
substances contain chemicals that can damage,
weaken or destroy plastic.
WARNING: When servicing, use only iden-
tical replacement parts. The use of any other
parts may create a hazard or cause damage to
the product.
WARNING: Use only accessories that are
recommended by the manufacturer for your
model. Accessories that may be suitable for
one tool may become hazardous when used
with another tool.
WARNING: Maintain tools with care. Keep
cutting tools sharp and clean.
Properly maintained tools, with sharp cutting
edges, are less likely to bind and are easier to
control.
WARNING: Check extension cords before
each use. If damaged, replace immediately.
Never use tool with a damaged cord.

TROUBLESHOOTING

MOTOR DOES NOT START
Tools is not plugged in: Check that all cords are
plugged in.
Fuse: Check the time-delayed fuse or circuit
breaker.
TOOL VIBRATES OR SHAKES
Damaged disc: Replace disc
Loose disc: Tighten arbor bolt.
If the machine presents other problems contact
your closest service center for maintenance.
E N G L I S H •

TECHNICAL DATA

VOLTAGE-FREQUENCY
NO LOAD SPEED
DISC CAPACITY
POWER
WEIGHT
U se r's m a nua l
120 V ~ 60 Hz
(3 000 - 10 000) r/min
4 1/2" (115 mm)
1 100 W
2,6 kg (5,7 lb)
13