Attaching A Cable To The Fault Mapper Pro - AEMC Instruments CA7026 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4..9

Attaching a Cable to the Fault Mapper Pro

1. Make sure that there is no power supply or equipment attached to the
cable to be tested.
2. Check that the far end of the cable is either open or shorted (not fitted
with a resistive termination).
3. Attach the Fault Mapper Pro
The cable attachment is via a BNC connector located at the top of the unit.
For unterminated cables use the alligator clip attachment provided.
Coaxial Cable:
Shielded Cable: Connect the Black clip to a wire adjacent to the
Twisted Pair:
Multi-conductor Cable: Connect the clips to any two wires.
1
®
Connect the Black clip to the center wire and the
Red clip to the shield/screen.
shield and the Red clip to the shield.
Separate out one pair and connect the red and black
clips to the two wires of the pair.
to one end of the cable to be tested.
Fault Mapper Pro
®
Coaxial Cable
Shielded Cable
Twisted Pair
Multi-conductor Cable
®
Model CA7026