Setting the minimum level
11) Light the burner as already described.
12) Turn the tap to the minimum flame position.
14) Use a thin straight screwdriver to turn the by-pass pin located
next to the tap rod (see fig. B).For LPG, turn the by-pass pin
The result should be a small, homogeneous flame which is
uniform around the entire burner ring. For the dual Triple
Flame version see fig. A. by-pass 1 central burner, by-pass 2
15) Finally, check that the burner does not go out when the tap is
turned quickly from the maximum to the minimum position.
These hobs are designed for installation in fitted kitchen units up to 600mm deep with
Any cabinet side panels taller than the height of the hob itself must be at least 150mm
away from the opening into which the hob is inserted.
13) Remove the control knobs.
fully clockwise.
both burners.
Building into fitted kitchen units
suitable characteristics.
B
A