TECHNICAL DA
TECHNICAL DAT T A SHEET
Working air pressure
Working temperature
Air consumption
Compatible oils
Pneumatic system pipes
Aerial Noise - Acoustic radiation pressure measured: 60 dBA
Tests carried out in conformity with the standards ISO/R 1680 - 1970. Instrument: LARSON DAVIS 800 B PRECISION ANALYSER
PHONOMETER in conformity with the standards IEC 804 E 651 class 1 set with a Larson Davis Ca 250 114/b 250 Hz calibrator
before and at the end of the measurements.
Measurements and dimensions - YAK 214/P
16
A SHEET
8 ÷ 10 bar
116 ÷ 145 psi
-20°C ÷ +50°C
-4°F ÷ 122°F
400 nl/min
Mobil DTE 10 EXCEL 46
Rilsan ø 6x4 mm
17.5 Kg
Weight
39 lb
166 mm
Max. stroke
6.5 in
20 t
1st stage capacity
22 ton (short)
10 t
2nd stage capacity
11 ton (short)
3rd stage capacity
-
4th stage capacity
-
5th stage capacity
-
A A
B B
C C
D D
E E
F F
G G
H H
K K
EN
EN
354-1052 mm
13.9-41.4 in
380 mm
15 in
360 mm
14.2 in
306 mm
12 in
140 mm
5.5 in
80 mm
3.1 in
86 mm
3.4 in
230 mm
9.1 in
140 mm
5.5 in