Technical Data Sheet - Cattini Oleopneumatica YAK 415/N Manual Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

EN

TECHNICAL DATA SHEET

Working air pressure
Working temperature
Air consumption
Compatible oils
Pneumatic system pipes
Aerial Noise
Acoustic radiation pressure measured: 60 dBA
Tests carried out in conformity with the standards ISO/R 1680 - 1970. Instrument: LARSON DAVIS 800 B PRECISION ANALYSER
PHONOMETER in conformity with the standards IEC 804 E 651 class 1 set with a Larson Davis Ca 250 114/b 250 Hz calibrator
before and at the end of the measurements.
Measurements and dimensions - YAK 415/N
8 > 10 bar
116 > 145 psi
-20°C > +50°C
-4°F > 122°F
600 nl/min
ATF Dexron IID
Rilsan ø 6x4 mm
Weight
Max. stroke
1st stage capacity
2nd stage capacity
3rd stage capacity
4th stage capacity
5th stage capacity
77 Kg
170 lb
250 mm
9.8 in
70 t
77 ton (short)
43 t
47 ton (short)
23 t
25 ton (short)
13 t
14 ton (short)
-
1430 mm
A
56.3 in
1320 mm
B
52 in
320 mm
C
12.6 in
150 mm
D
5.9 in
250 mm
E
9.8 in
60 mm
F
2.4 in
68 mm
G
2.7 in
56 mm
H
2.2 in
66 mm
K
2.6 in
350 mm
L
13.8 in
240 mm
M
9.4 in