Making Air Inlet And Outlet Vents - Dometic 10-Serie Instrucciones De Uso

Ocultar thumbs Ver también para 10-Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
RMD10.5(X)(T)(S)
Side gap distance of 5 mm to 10 mm between refrigerator and
furniture (C)
➤ Glue the double lipped sealing (see chapter "Accessories" on page 16) on the
side of the furniture (4).
➤ Push the refrigerator-oven combination against the double lipped sealing on fur-
niture.
✔ The space behind the refrigerator is sealed to the interior of the vehicle.
4.3

Making air inlet and outlet vents

I
NOTE
• Deviations from the inlet and outlet variations shown here must be
approved by the manufacturer.
• At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been pro-
vided.
➤ Make an air inlet vent and an air outlet vent in the outer wall with the size of
249 mm x 490 mm.
When doing so, observe the information in chapter "Preparing the installation"
on page 16.
If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the
niche, install an inlet vent in the floor. Any leaking gas can thus flow downwards.
➤ Make an air inlet vent of at least Ø 40 mm in the floor (fig. 8 1, page 8) behind
the refrigerator near the gas burner.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 8 2, page 8).
If you have to use a roof vent instead of the air outlet vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions.
When doing so, observe the information in chapter "Preparing the installation"
on page 16.
EN
Installing the refrigerator
19

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Rmd10.5xsRmd 10.5xt

Tabla de contenido