IMPORTANT SAFETY INSTRUCTIONS
Read through all the instructions before
starting to use the appliance. Keep this
manual in a safe place for future reference.
These instructions are also available on our
website. Please visit www.hot-europe.com.
WARNING: Unplug the appliance during filling
and cleaning
• Read all instructions before using this
humidifier.
• Always place this humidifier on a firm, flat
and level surface. This humidifier may not
work properly on an uneven surface.
• Place this humidifier in an area where it is
not accessible to children.
• Do not place the humidifier near any heat
sources such as stoves, radiators, and
heaters.
• Do not use the humidifier outdoors.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
• The appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use of
this appliance in a safe way and understand
the hazards involved. Children shall not
play with the appliance. Cleaning and user
maintenance shall not be made by children
without supervision.
• To disconnect the humidifier, first turn
controls to the OFF position, then grip the
plug and pull it from the wall outlet. Never
pull by the cord.
• A loose fit between the AC outlet
(receptacle) and plug may cause overheating
and a distortion of the plug. Contact a
qualified electrician to replace loose or worn
outlet.
8
All manuals and user guides at all-guides.com
• Never tilt or attempt to move the humidifier
while it is operating or filled with water.
UNPLUG the humidifier before moving.
• This humidifier requires regular cleaning.
Refer to the CLEANING instructions provided.
Never clean the humidifier in any manner
other than as instructed in this manual.
• Do not direct moisture flow directly at
individuals, walls or furniture.
• When a humidifier is used in a closed room
or small rooms, check periodically for proper
ventilation, as excessive humidity can cause
condensation stains on walls.
• Turn the humidifier OFF if you notice
moisture on the inside of your windows. For
proper humidity reading use a hygrometer,
which is available in many hardware and
department stores, or by ordering one from
the manufacturer.
• Do not touch the nebulizer while the unit is
plugged in as burns could result.
• Do not place the product directly on wood
furniture or other surfaces that could be
damaged by water or liquids. Kaz will not
accept responsibility for property damage
caused by spillage or leaking.
COMPONENTS (See page 3)
1. Carrying handle
2. Directional mist nozzle
3. Water tank
4. Tank cap
5. Base
6. Power switch and intensity control
7. Pilot light
8. Scent pad heater
9. Optional Demineralization or Antibacterial cartridge (not
included in pack)
FILLING (See appendix A on page 4)
Remove the Water Tank by grasping handle and pulling straight
up (Fig. 1). Set aside.
• Turn the Water Tank upside down so that the Tank Cap
is facing up; unscrew the Tank Cap by turning it counter-
clockwise and set aside.
• Fill the Water Tank with clean, cool, tap water (Fig. 2).
• Replace the Tank Cap by firmly turning clockwise . Turn the
Water Tank upright and check the Tank Cap for leaks. If any
water drips from the Tank Cap, remove it and re-tighten. Use
of very cold water may temporarily reduce the mist output.
Never fill the humidifier with hot or warm water as this could
cause damage and void your warranty.
NOTE: When carrying the filled Water Tank, please use
the handle and place your other hand under the tank for
additional support.
• Position the Water Tank in the humidifier and push into place.
Some water will empty into the Base.
• Once the filled tank has been positioned, do not attempt
to move the humidifier. If it has to be moved, unplug the
humidifier and remove the Water Tank first.
FIRST TIME OF USE
Before using the unit for the first time, you should note the
following points:
• Remove all packing material from the unit
• It is recommended that you disinfect your humidifier prior to
first use. See cleaning Instructions.
• Select a firm, level location at least 15 cm from any walls for
proper airflow.
• Place the humidifier on a water resistant surface.
OPERATING INSTRUCTIONS
A) POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET
HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.
With the power switch in the OFF position, plug the filled
humidifier into an outlet.
• Turn the Power Switch clockwise to the on position. The
Water Window will illuminate.
• Set your desired output by turning the knob clockwise. To
operate on HIGH, turn the dial to the end.
• Mist will not appear immediately; allow a few minutes for
the water to fill the reservoir. If you are using the optional
Demineralization Cartridge (Fig. 3), it may take up to 15
minutes for the filtering material to become saturated and for
mist to appear.
• The unit will shut off when it is out of water.
• Turn the humidifier off before removing and refilling the
Water Tank. When the Water Tank is empty the mist will stop
although the fan will continue to operate.
B) SCENT PAD HEATER DIRECTIONS FOR USE
(see appendix C on page 5)
• Turn off and unplug your humidifier.
• Remove the water tank and locate the scent pad slot on the
base (Fig. 4).
• Place one scent pad in the slot, being careful not to touch
the scent pad with your hands.
If your hands do come in contact with the pad, please wash
them thoroughly as the menthol can be an irritant.
• Replace the tank and turn the unit on.
Note: As long as your humidifier is on, the scent pad heater
will also be activated. This area can be warm to the touch.
WARNING:
Pad may present a choking hazard. Keep out of reach of children
and pets.
Flammable liquid and vapour (H226).
Causes skin irritation (H315).
May cause an allergic skin reaction (H317).
Causes serious eye irritation (H319).
Toxic to aquatic life with long lasting effects (H411).
Keep out of reach of children (P102).
Keep away from heat/sparks/open flames/hot surfaces. -
No smoking (P210).
Avoid release to the environment (P273).
IF ON SKIN: Wash with plenty of soap and water (P302+P352).
IF IN EYES: Rinse cautiously with water for several minutes.
Remove contact lenses, if present and easy to do. Continue
rinsing (P305+P351+P338).
If skin irritation or rash occurs: Get medical advice/ attention
(P333+P313).
Do not use for babies less than 36 month old, for more
than 16 hours in a 24 hour period and/or not more than
+
36m*
2 pads in a 24 hour period.
Contains Menthol, Eucalyptus oil, Cedarleaf oil
C) ANTIBACTERIAL CARTRIDGE USE
(see appendix B on page 5)
In order to have a pure mist, the pathogens particles of the
water must be killed . In the water the following elements
can be found:
HOW IT WORKS:
The antibacterial cartridge is a cartridge filled with carbon.
The active carbon acts like a filter to treat the water and
carriers silver to maximize the effectiveness of water
treatment.
One gram of silver nanoparticles is all that is required to give
antibacterial proprieties to the cartridge and kill the bacteria,
viruses and fungus.
After antibacterial cartridge treatment, bacteria, viruses and
Fungus are killed.
9