Cap 2 Installation; Unpacking; Electrical Connection; Positioning - Eurofred 7FEB0015 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

DISHWASHER INSTRUCTION MANUAL
Proper installation is essential to the good operation of the appliance. Some of the data required for
installation of the appliance are given on the nameplate on its RH body panel, and a copy is included on
the cover page of this manual.
The appliance may only be installed by qualified persons authorised to do so.
Check the condition of the packaging, and note
any evident damage on the shipping bill. Remove
the packaging and check that the appliance is in
good condition; immediately report any damage to
the reseller and the shipping agent by fax or
registered letter with return receipt. If the damage
is such as to compromise the safety of the
appliance, do not install or operate it until it has
been inspected by a qualified technician.
The packaging (plastic bags, expanded polystyrene,
nails, etc. ) are hazardous and must not be left within the
reach of children or pets.
 Check that there are no objects or materials
in the installation area which may be
damaged by the steam emitted by the
appliance during operation, or if there are,
make sure they are properly protected.
 Before positioning the appliance, set up the
electrical power supply, water supply and
drain connections
 The floor or build-in unit must be rated to
support the weight of the appliance
 To ensure that it is stable, level the
appliance with its four feet.
 The
appliance
installation only; any other approaches must
be agreed with and approved by the
manufacturer.
 Remove the protective film from its body
panels before operating the dishwasher.

2.1 Unpacking

2.2 Positioning

is
intended
for
fixed
Cap 2

2.3 Electrical connection

 The power supply must be fitted with a
omnipolar circuit breaker (master power
switch) to break all contacts including
neutral, with a contact gap of at least 3 mm
and thermal cutout or fuses, which must be
set or rated to the power indicated on the
machine's nameplate.
 The master power switch must be fitted to
the power line in the vicinity of the
installation and may be connected to only
one machine at a time.
 The mains voltage and frequency must
match the nameplate ratings.
 The installation must include a grounding
system
conforming
electrical safety legislation, to protect the
operator and the appliance itself.
 The power line, which must be H07RN-F
unit, must not be stretched or crushed
during normal operation or maintenance.
 The appliance must also be connected to an
equipotential system with the screw marked
with the symbol.
 The equipotential cable must have a cross
section of 10 mm².
 Respect the polarities indicated in the wiring
diagram.
 For further information, refer to the wiring
diagram.
Do not use multi-sockets, adapters, cables
of an inadequate cross section or type or
with
extensions
established
electrical
regulations.
UK
INSTALLATION
with
established
not
conforming
installation
Page 3 of 10
to
Tabla de contenido