A U T O M A T I C O P E R A T I O N I N M U L T I S P L I T
CONFIGURATION
When the air conditioning system configuration is multisplit
and there is more than one indoor unit connected, the
automatic mode operates as follows:
- the first unit that switches on the system also decides the
operation mode (cooling or heating) for all the other units
that will be switched on after the first one;
- when the system has been switched on in cooling mode
and one unit is activated in heating mode, an error will
be signaled for this unit (wrong operating mode). If the
same unit is switched on in "automatic" mode and the
desired temperature is lower than the detected ambient
temperature, the unit will operate in cooling mode, like the
other units of the system; on the contrary, if the desired
temperature is higher than the detected one, the unit will
operate in fan mode;
- when the system has been switched on in heating mode
and one unit is activated in cooling mode, an error will
be signaled for this unit (wrong operating mode). If the
same unit is switched on in "automatic" mode and the
desired temperature is higher than the detected ambient
temperature, the unit will operate in heating mode, like the
other units of the system; on the contrary, if the desired
temperature is lower than the detected one, the unit will
operate in fan mode.

DEHUMIDIFYING (DRY)

1. Set the
button to DRY. The icon
2. Press the +/- buttons (temperature selection) to set the
desired temperature (the temperature range is between
32 °C max. and 10 °C min.).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
NOTE
Use DRY operation when you want to reduce the humidity
in the room.
Dehumidifying operation is adjusted both by the difference
between set temperature and air temperature, and by the
value of relative humidity, detected by the sensor.
During DRY operation, the fan speed is automatically
set (Remote control lamp
overcooling.
Dry operation is not possible if the indoor temperature is
10 °C or less.
When room temperature is above set value, the unit
operates to dehumidificate so efficient as possible.
When room temperature is below set value, the unit will
not stop, it will proceed operating with low power to
dehumificate and, in small spaces, temperature could
drop below the set temperature.
AQFST-12-18-USO.indd 7
AQFST-12-18-USO.indd 7
is displayed.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
is ON) to prevent

FAN ONLY

If you want to make air circulate without any temperature
control, press
button until only the
appears on the display.

ADJUSTING THE FAN SPEED

AUTOMATIC
Simply set the FAN selector to the
automatically controls the fan speed when the AUTO mode
is selected. When the air conditioner starts operating, in
heating or cooling, the fan speed varies according to the
thermal load of the room.
MANUAL
If you want to manually adjust speed just set the FAN
selector as desired.
High speed
Med. speed
NIGHT MODE / ENERGY SAVING
This mode enables you to save energy.
1. Set the
or
selector to cool, dry or heat.
2. Press the
button.
3. The
mark appears on the display. Press the
button again to release the function.
What does the NIGHT mode mean?
When you select the NIGHT mode, the air conditioner will
modify automatically the set temperature after 60 minutes.
This enables you to save energy without sacrificing your
comfort.
OPERATING MODE
Heating
Cooling and Dry
NOTA
During the NIGHT mode the internal fan speed is
automatically lowered and reduces the noise.

HIGH POWER MODE

When this mode is active the internal fan speed is set
automatically and the air conditioner operates at the
maximum power in the selected operating mode (cooling
or heating).
1. Press the
HIGH POWER button.
3. The
mark appears on the display. Press the button
again to release the function..
NOTE
During the high power operation the room temperature
could not correspond to the set temperature.
7 7
fan symbol
position.The unit
Low speed
SET TEMPERATURE CHANGE
Lowered by 2 °C
Raised by 1 °C