All manuals and user guides at all-guides.com
PX4 AIR PAPR
INTRODUCTION CONTINUED
Note: the EN 12941: 1998 + A1: 2003 + A2:
2008 standard is a requirement for loose
fitting respirators such as helmets and face
shields (03-911) and the 12942: 1998 + A1:
2004 + A2: 2008 standard is a requirement
for tight fitting respirators such as full face
masks and half face masks (03-912 Low
Flow). For more information on the respirator
refer to the specific Respirators User
Instruction Manual.
SERVICE LIFE OF HE FILTER,
PREFILTER AND SPARK ARRESTOR
The HE filter should be replaced if the airflow
alarm is activated, or the flow indicator
reading falls below the 6cfm (170 slpm) for
the 03-911 and 4.2cfm (120 slpm) for 03-912
minimum airflow. The HE filter should also
be replaced if there is damage to the filter
media, such as a tear or puncture, etc... or the
filter media becomes wet. The PX4 AIR
approved to only be used with genuine RPB
filter cartridges.
The OV/AG/HE cartridge should be replaced
after each use or if any of the above HE filter
conditions apply.
The Prefilter is recommended to be replaced
when it is dirty or damaged or at the same
time as the HE Filter. The Spark Arrestor
should be replaced if it becomes damaged or
clogged with debris.
4
®
WARRANTY
All RPB
products are covered by a
®
manufactures warranty of 3 months. The
manufacturer warranty covers defects in
material, workmanship and does not cover
damage caused by misuse or abuse. RPB
only obligation and your exclusive remedy
shall be to repair, replace or refund the
purchase price of such parts or products
upon the presentation of proof of purchase.
Maximum liability is in no case to exceed the
value of the RPB
APPROVAL
The RPB
PX4 AIR
®
of the European Community Directive
89/686/EEC, (Personal Protective
Equipment Device).
The RPB
PX4 AIR
®
EN 12941: 1998 + A1: 2003 + A2: 2008
is
®
TH2/TH3 P R SL Respirator by:
®
Apave Sudeurope SAS (0082)
8 rue Jean-Jacques Vernazza
CS 60193
13322 Marseille Cedex 16
France
Under Article 10 and the quality systems
are approved under Article 11b by INSPEC
International (0194)
Salford University Business Park
56 Leslie Hough Way
Salford M6 6AJ
United Kingdom
's
®
Product involved.
®
meets the requirements
®
is approved as an
®