All manuals and user guides at all-guides.com
PX4 AIR PAPR
PRODUCT SPECIFICATIONS AND DATA
AIR FLOW
OPERATING TEMPERATURE
OPERATING NOISE
STORAGE TEMPERATURE
BATTERY RUN TIMES
BATTERY CHARGING
22
®
Speed 1: Greater than 170slpm (Nominal 180slpm) [120slpm, Nominal
130slpm (03-912)]
Speed 2: Greater than 210slpm [135slpm (03-912)]
Speed 3: Greater than 240slpm [150slpm (03-912)]
-10° to 40°C. If the unit is operated outside this temperature range for 10
minutes the battery alarm will activate.
If the internal battery temperature reaches 60°C the unit will completely
shut down.
Speed 1: 57 dBA at 300mm from the unit.
Speed 2: 59 dBA at 300mm from the unit.
Speed 3: 62 dBA at 300mm from the unit.
Note: readings were taken at the distance listed from the front of the unit
when connected to a T100
Respirator at the 3 speed settings.
®
-10° to 45°C at a Relevant Humidity of less than 90%. RPB
recommends that the device is store at 10° to 30°C as the optimal
temperature range for storage, to maximise the life of the battery.
Lithium-polymer
OV/AG/HE Cartridge
HE Filter
Speed 1: 6-7 hours
Speed 1: 10-13 hours
Speed 2:
Speed 2: 7-10 hours
Speed 3:
Speed 3: 6-8 hours
Note that these times are estimated from testing using a new battery
and new clean filter at 21°C. These times could be longer or shorter
depending on environments and configurations.
Note: you should consult with your transport agent specialist before
transporting Lithium-polymer batteries.
3 hours
TABLE 1.2
®
N/A See Special or Critical
User Instructions on page 16.