Design And Function - WIKA TR33 Manual De Instrucciones

Termorresistencia miniatura
Ocultar thumbs Ver también para TR33:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. Specifications / 4. Design and function
Patents, property rights
M12 x 1 adapter to angular connector
DIN EN 175301-803
Conditions for outdoor use (for UL approval only)
The instrument is suitable for applications with pollution degree 3.
The power supply must be suitable for operation above 2,000 m
should the temperature transmitter be used at this altitude.
The instrument shall be installed in locations sheltered from the
weather.
The instrument shall be installed "sun/UV radiation protected".
For further specifications see WIKA data sheet TE 60.33 and the order
documentation.

4. Design and function

4.1 Description
The model TR33 resistance thermometer consists of a thermowell with
a fixed process connection and is screwed directly into the process.
It is designed to be impact and vibration resistant and all electrical
components are protected against humidity (IP67 or IP69K).
The vibration resistance conforms to IEC 60751 (20 g, dependent on
the instrument version). The impact resistance of all versions meets
the requirements of IEC 60751. Ensure that mechanical loads on the
connector are minimised, especially in case of increased ambient
temperatures or strong vibration loads.
The electrical connection is made via an M12 x 1 circular connector.
An adapter for electrical connection with angular connector per
DIN EN 175301-803 is optionally available.
WIKA operating instructions model TR33
No. 001370985
EN
13
Tabla de contenido
loading

Tabla de contenido