3. Specifications / 4. Design and function
Vibration resistance
Depending on the installation situation, medium, temperature and insertion
length vibration resistance in accordance with DIN EN 60 751, can be as high as
10 g.
Shock resistance
up to 500 g, depending on installation situation, medium and temperature
Working pressure
max. 600 bar, depending on medium, temperature and thermowell design
Electrical connection
Plug, AMP Junior Power Timer
FASTON blade terminal 6.3 x 0.8 mm
FASTON blade terminal 4.8 x 0.8 mm
Circular connector, M12 x 1
Connector, Deutsch DT04-2P
Bayonet connector, DIN 72 585
Ingress protection
IP 66 / IP 67 once connected (provided installation has been carried out in the
correct manner)
For further specifications see WIKA Data Sheet TE 67.10 and the order
documentation.
4. Design and function
4.1 Description
The Model TF35 screw-in thermometer consists of a thermowell with integrated
measuring element and a built-in connector. The screw-in thermometer can be
screwed in directly into the process.
Each electrical component is protected against splash water.
Electrical connection is made via the connector.
The Model TF35 screw-in thermometer has a high shock- and vibration-
resistance. The vibration resistance of the standard version is up to 10 g. The
shock resistance exceeds the requirements of DIN EN 60 751.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
WIKA Operating Instructions Screw-in Thermometers, Model TF35
GB
9