Interface Specifications - Sanyo DSR-M810P Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 164
1

INTERFACE SPECIFICATIONS

RS-485 specifications
Data format
Mode
Asynchronous
Character length
8 bits
Data transmission speed 2400, 4800, 9600, 19200 bps
Parity check
None
Stop bit
1 bit
Communication protocol
A proprietary Sanyo protocol (SSP: Security Serial
Protocol) is used. Use of a special controller for operation
is recommended. To obtain this controller, contact a Sanyo
Authorized Service Center.
All manuals and user guides at all-guides.com
48
RS-485 termination switch settings
Termination settings
When connecting multiple devices, you must make
termination settings on both end devices.
Set the RS-485 termination switch of both end devices
to ON.
Be sure to set the RS-485 termination switches of all
devices in between (devices other than the first and last
devices) to OFF.
If you don't make the correct termination settings, the
incorrect data will be transmitted to each device.
Example
System controller
LAN
MIC IN
IN
OUT
AC IN
Digital video recorder
Time – lapse VCR
ON
Termination
switch
OFF
VIDEO
IN
OUT
NTSC
PAL
ON
RS485
termination
OFF
ON
Termination
switch
OFF
English
Tabla de contenido
loading

Tabla de contenido