Exporting Case Data To An External Device - Medtronic autoLog IQ Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Size: 7 x 9 in (178 x 229 mm)
• Suction Line Lot #
• Heparin Lot #
• ACD-A Lot #
• Notes
• Bowl #
• Fill (mL)
• Fill start time
• Wash (mL)
• Wash start time
• Empty (mL)
• Empty start time
• Incomplete Fill?
• Total
• End of data
Figure 33. Case data file (example only)
Print Date
Device SN
13-Oct-16
ATLGIQ
Case Date
Patient ID
20-Jan-16
Bowl #
Fill (mL.)
1
2
3
Total
End of data

14.4 Exporting case data to an external device

Case data can be exported to an external device that has been configured with software that supports device case data exports.
Contact your Medtronic service representative for support.
Note: When the device is connected to an external device, it is more susceptible to electrostatic discharge, which may result in the
interruption of data export. Data export may be restarted if interrupted.
1. Connect a USB cable (type A male to type B male) from the type B USB port on the device (Figure 9) to a type A port on the
external device.
Warning: USB cable length must not exceed 3 m (118 in).
Note: Ensure that any PC, external device, or external information technology equipment connected to the type B USB port on
the device is certified equipment that complies with IEC 60950-1.
2. From the case list screen, select the desired cases and press
3. The message Selected cases received? appears.
• Select Yes if the data was successfully received.
• Select No if the export was not received completely. The message Reset the connection and try again. appears. Select
OK. The message Download failed appears. Select OK. To retry the export, check the USB cable connection, and then
press
4. After successful export, The message Download is complete. Delete selected cases? appears.
• Select Yes to delete the exported cases from the device.
• Select No to keep the exported cases stored in the device.
5. Remove the USB cable.
English
M967226A006 1B Medtronic Confidential
System
name
Operator ID
Reservoir
Lot #
123456789
223456789
116909914
Fill start time Wash (mL.)
520
9:00
250
535
11:00
250
552
11:15
250
1607
750
.
Wash Kit
Suction
Heparin Lot # ACD-A Lot #
Line Lot #
Lot #
75881868
10233729
4456789
Wash start
Empty
Empty start
time
(mL.)
time
90
9:03
9:01
11:01
135
11:03
100
11:18
11:16
325
.
34
Notes
Ortho case.
5567891
Incomplete
Fill?
No
No
No
Composed: 2018-06-08 06:06:55
PSJ - Size-selectable package manual 02-MAY-2018
502431-132
Tabla de contenido
loading

Tabla de contenido