WORKING WITH PLUs
You can save the price and/or tare for frequently sold
goods in the scale's PLU memory and recall it later. In
the factory setting, unit price and tare are saved in
a PLU.
CREATING A PLU
1.
Enter the unit price.
2. Press and hold the PLU key
until a long beep can be
heard.
appears in the
P
weight display. (See Figure 4)
3. Enter the PLU number
between 1 and 9999.
4. Wait until the scale beeps
twice. The PLU is stored and all displays return to zero.
• To save the tare weight in the PLU, tare the
corresponding container before entering the unit
price.
• The scale can store 100 PLUs. If the memory is full
and you want to store a new PLU, the messages
and
are displayed. You can either overwrite
Delete
a specific PLU or delete the whole PLU memory.
– To overwrite an existing PLU, press the C key and
create a new PLU with the number you want to
overwrite.
– To delete the whole PLU memory, press the ENTER
(ON/OFF) key.
CALLING UP PLUs
Depending on the setting of operator setup step 7, there
are two ways to call up PLUs.
CALLING UP VIA PLU KEY
(Factory setting, operator setup step 7 = off)
1.
Place item on the scale.
(See Figure 5)
2. Enter the corresponding
PLU number and press
the PLU key. Unit price
and price to pay are
displayed.
3. Remove item from scale.
All displays return to 0.
PAGE 3 OF 39
OPERATION CONTINUED
Figure 4
0 ... 9
0 ... 9
Full
Figure 5
0 ... 9
CALLING UP PLU AUTOMATICALLY
(Operator setup step 7 = on)
1.
Place the item on the
scale. (See Figure 6)
2. Enter the corresponding
PLU number. The PLU is
called up automatically.
Unit price and price to
pay are displayed.
3. Remove the item from the
scale. All displays return to 0.
USING PLU PRESET KEYS
You can save the most important PLUs to the keys in the
left-hand key field.
Depending on the setting of operator setup step 14, one
or two PLUs can be assigned to a PLU preset key.
PLU PRESET KEYS WITH ONE PLU
(Operator setup step 14 = off)
STORING ONE PLU TO
A PRESET KEY
1.
Enter the unit price or
recall PLU. (See Figure 7)
2. Press and hold the
desired preset key, e.g.,
M1, until a long beep
can be heard. Two short
beeps indicate that the data has been stored.
CALLING UP PLUs
WITH PRESET KEYS
1.
Place the item on the
scale. (See Figure 8)
2. Press the corresponding
preset key, e.g., M1. Unit
price and price to pay
are displayed.
3. Remove the item from the scale. All displays return
to zero.
Figure 6
0 ... 9
Figure 7
0 ... 9
M1
Figure 8
M1
0721 IH-5116