Connecting The Electrical Power To The Generator - Dometic ePower T Instrucciones De Montaje

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107
All manuals and user guides at all-guides.com

Connecting the electrical power to the generator

7.6
Mounting the control panel
I
NOTE
You find detailed information about mounting the control panel in
the installation manual of the eCore.
8
Connecting the electrical power to the
generator
D
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
I
NOTE
Observe the applicable guidelines in the country of the consumer.
8.1
Important notes on the electrical connection
 Only a qualified electrician should connect the generator to the electrical
power.
 Check that the voltage specification on the type plate is the same as that
of the power supply.
 Do not lay the 230 Vw mains cable and the 12 Vg cable together in the
same cable duct.
 Do not lay cables which are loose or bent next to electrically conductive
material (metal).
 Connect the generator to a power circuit which can supply the necessary
current (see chapter "Technical data" on page 46).
 Connect the generator to a starter battery with the necessary capacity
(see chapter "Technical data" on page 46).
 Select the cross-section of the cable as follows:
– Battery connection (length < 6 m): 10 mm²
– Battery connection (length > 6 m): 16 mm²
 Install a manual main switch which can disconnect all the consumers from
the generator.
32
ePower T, ePower T LPG
EN