All manuals and user guides at all-guides.com
Connecting the electrical power to the generator
7.6
Mounting the control panel
I
NOTE
You find detailed information about mounting the control panel in
the installation manual of the eCore.
8
Connecting the electrical power to the
generator
D
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
I
NOTE
Observe the applicable guidelines in the country of the consumer.
8.1
Important notes on the electrical connection
Only a qualified electrician should connect the generator to the electrical
power.
Check that the voltage specification on the type plate is the same as that
of the power supply.
Do not lay the 230 Vw mains cable and the 12 Vg cable together in the
same cable duct.
Do not lay cables which are loose or bent next to electrically conductive
material (metal).
Connect the generator to a power circuit which can supply the necessary
current (see chapter "Technical data" on page 46).
Connect the generator to a starter battery with the necessary capacity
(see chapter "Technical data" on page 46).
Select the cross-section of the cable as follows:
– Battery connection (length < 6 m): 10 mm²
– Battery connection (length > 6 m): 16 mm²
Install a manual main switch which can disconnect all the consumers from
the generator.
32
ePower T, ePower T LPG
EN