– as a reference value for the fish population in the pond: approx. 2 ft (60 cm) fish length in 260 gal (1 m
water.
– as a pond pump for FiltoClear 3000: pump max. 2100 Gph (8000 l/h).
– as a pond pump for FiltoClear 4000: pump max. 2600 Gph (10000 l/h).
– as a pond pump for FiltoClear 8000: pump max. 4200 Gph (16000 l/h)
Symbols on the unit
The warning symbols on the unit have the following meaning:
Risk of personal injury if used incorrectly
Incorrect use of the unit can cause injury or damage to assets. Always read the instructions for use first.
Risk of personal injury caused by a general source of danger
Dangerous UVC radiation. Health hazard for eyes and skin caused by light flash. Only operate the UV-C
lamp inside the housing.
The symbols on the unit relating to its use have the following meaning:
Protected against touching dangerous components. Splash water protected.
Protect from direct sun radiation.
Dismantle at temperatures of 0 °C and below.
Installation
Figure (A)
To be taken into consideration for planning:
– Spacing between unit and water: min. 6.6 ft (2 m) (safety spacing!).
– Do not expose the unit to direct sun radiation.
– Water return point. OASE recommend: Route the return hose such that the clean water is indirectly returned to
the pond, e.g. through a water course. In this manner it will be additionally enriched with oxygen.
– Height difference between filter lid and water return point: max. 6.6 ft (2 m).
Installation possibility 1: Bury close to the pond.
Dig a hole close to the pond and place the container into the hole up to the mark (B 11).
Installation possibility 2: Placement close to the pond.
Place the unit close to the pond where it is flood protected (e.g. hidden behind shrubs). The ground must be firm and
level.
Connecting a filter pump
A filter pump is required to operate the pressure filter (only contained as a set in the scope of delivery). Only connect to
the pump by means of pressure hoses approved for at least 2.9 psi (0.2 bar) or the maximum pump pressure.
Hoses with an internal diameter of 1 1/2" or 2" can be connected to the unit.