For this kind of certification, the product markings are as follows:
Protection Level
The following table summarize and explain the performance level reported on the product
marking as a passive impact protector:
Standard
Tested Area
Used for
tests
1621-
Central Back
2:2014
The EU Declaration of Conformity of this PPE (as established by the REG. EU 2016/425) can
be downloaded at: eudeclaration.alpinestars.com.
Pyrotechnic Articles
The Tech-Air
5 System contains two pyrotechnically activated cold gas inflators, and as
®
such, the whole item is considered as an "AIRBAG MODULE" category P1 under EU Directive
2013/29. As such a EU Type Examination (Module B) has been conducted on the design of
the System, and a EU Type Examination and Audit (Module E) has been conducted on the
assembly of the System.
The EU Type Examination and Audit have been conducted by Notified Body #0080, Ineris,
Parc Technologique ALATA BP2, Verneuil-en-Halatte, 60550, France.
Electromagnetic Stability
The Electronic Unit of the Tech-Air
regulations for electronic and radio devices.
FCC compliance Statement:
The System has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
26 EN
Name of the
Manufacturer
Product
Identification Code
Indicates that
the product is for
motorcycle use
Indicates that the
product meets
Central Back, Level
1 requirements
Temperature
Force Transmitted
Average 10.05kN
20°
Peak 18.98kN
5 System has been tested according to different
®
Protector Size
(Waist to
Shoulder)
Indicates that
the product has
been tested
according the
1621-2:2014
standard
Level
Level 1 requirements:
average value ≤ 18kN; No
impact above 24kN
Level 2 requirements:
average value ≤ 9kN; No
impacts above 12kN
Level 1