3.1.2 Moving Tools Between Gateways
If a Wireless Tool has established a secure link with a Gateway (1) and
you want to move the tool to a new Gateway(2), the tool's security key
needs to be reset.
3.1.2.1 Resetting a Wireless Tools Security Key:
1. First Turn off the Tool, and then block it on the Gateway tab of the
Gateway(1) in DSA 4.0.
2. Wait for DSA 4.0 to report the End Node is offline.
3. Turn on the tool.
4. Press and hold the Wireless Radio button.
5. If the display shows On, continue to hold the button and then go
to step 9.
6. If the display shows OFF, release the button.
7. The display will show On and then return to displaying the live
reading.
8. Press and Hold the Radio Button again.
9. The Display will then show "DSA".
10. Press the In/mm button once to see "RESEt." on the display.
11. Release the Radio Button. The security Key has been erased.
12. Move within range of the new Gateway(2) and follow
"Establishing First Communications" above.
3.1.2.2 Moving to Another Gateway(1):
If you move the Wireless Tool to a Gateway(1) that has already
exchanged security keys with the wireless tool, then the security keys
for both the wireless tool and gateway need to be erased.
Follow " Resetting a Wireless Tools Security Key:" above steps 1-11..
Keep the Wireless Tool on, and then go to the DSA 4.0 application and
navigate to the Gateways tab.
– Note the UID number label on the Wireless Tool and select that UID
number in the Device Selection drop down box.
– Press the "Reset Security Key" button below the drop down.
The tool should change to Online, and a secure link has been
established.
For more information about the DSA 4.0 software please consult the
Datasure® Advanced 4.0 User Guide.