• connect the machine to its own electrical connection fitted with a suitable 30-mA current
sensitive circuit breaker;
• fit power supply protection fuses sized in compliance with specifications in the main
wiring diagram of this manual;
• provide the workshop electric installation with an efficient grounding circuit.
- Prevent unauthorised use of the machine, always disconnect the power supply plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
board and without the use of a plug, install a key-operated switch or suitable lock-out device
to restrict machine use exclusively to qualified personnel.
CAUTION
For the machine correct functioning it is vital to have a good ground connection.
NEVER connect the machine ground wire to a gas pipe, water pipe, telephone cable
or any other unsuitable object.

ComPrESSED air HooK-UP

CAUTION
All compressed air hook-ups must be carried out by qualified personnel only.
- The hook-up to the workshop's pneumatic system must ensure a minimum pressure
of 7 bar (100 psi). Lower pressure levels may prevent the machine's AUTOMATIC
WHEEL LOCKING SYSTEM PL from working properly.
- A universal union is used for connection to the compressed air system. No special or
additional adaptor is needed for connection. A pressure-resistant hose with 6mm inner
diameter and 14mm outer diameter must be fastened to the notched union using the
clamp provided with the machine.
CAUTION
Non-compliance with the instructions and danger warnings can cause serious injuries
to the operator or other persons.
Do not operate the machine until you have read and understood all the danger/warn-
ing notices in this manual.
In order to operate the machine correctly, it is necessary to be a qualified and authorised
operator, able to be trained and to know the safety regulations. Operators are expressly
forbidden from using the machine under the influence of alcohol or drugs capable of affect-
ing physical and mental capacity.
The following conditions are essential:
- the operator must be able to read and understand the contents of this manual;
- have a thorough knowledge of the features and characteristics of the machine;