General Characteristics - CAME ZL160 Manual De Instrucciones

Ocultar thumbs Ver también para ZL160:
Tabla de contenido
Description
The ZL160 control panel is suitable for con-
trolling an automatic system for the FLEX se-
ries swing gates powered by 24V d.c. with ca-
pacity up to 48W, frequency 50-60 Hz.
Wholly designed and built by CAME CAN-
CELLI AUTOMATICI S.p.A., it meets UNI
8612 regulations in force. ABS case, which
has an IP54 protection level, with air recycling
inlet.
The circuit requires 230V (AC) on terminal
blocks L1 and L2, and is protected with 1.6A
fuse, whilst the low voltage command devices
are protected by a 3,15A fuse.
The accessories total capacity (24V) should
not exceed 40W.
The control panel includes an amperometric
sensor that constantly checks the force devel-
oped by the motor when opening or closing: if
this exceeds the preset level (for example, in
the event of an obstacle blocking movement), it
becomes operative and stops the motor.
Safety
Photocells can be connected to abtain:
- Re-opening during closure (2-C1), if the
photocells identify an obstacle while the gate
is closing, they will reverse the direction of
movement until the gate is completely open;
- Total stop (1-2), shutdown of gate
movement without automatic closing, a
pushbutton or radio remote control must be
actuated to resume movement.
Optional accessories
- 12V Electric lock (2-ES);
- Gate open pilot lamp (3W max.). A lamp that
signals the gate's open position and that goes
out when the gate is in the closed position.
Connected to terminals 10-5.
- LB54 Board . Powers the reduction gears

GENERAL CHARACTERISTICS

through batteries in case of a power outage.
After the power supply is restored, it also re-
charges the batteries.
Other functions
- Automatic closing. The automatic closing
timer is automatically activated at the end of
the opening cycle. The preset, adjustable
automatic closing time is automatically
interrupted by the activation of any safety
system, and is deactivated after a STOP
command or in case of power failure;
- "Operator present" . Gate operates only
when the pushbutton is held down (the radio
remote control system is deactivated). It is
activated when the T.L. trimmer is set to the
minimum;
- Hammer movement. At every opening com-
mand, the wings press the closing stop-ledge
for a second, thus facilitating the release op-
eration of the electric lock connected to termi-
nals 2-ES.
It is only active if the wings are closed and at
the end of the work time.
Adjiustments
- Automatic closure time;
- Operating time.
Important! Disconnect the unit from the
main power lines before carrying out any
operation inside the unit.
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
-3-
Tabla de contenido