General Characteristics - CAME Z Serie Manual De Instrucciones

Ocultar thumbs Ver también para Z Serie:
Tabla de contenido
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Description of control panel
Control panel for gear motors, powered
by 220V single-phase or 380V three-
phase; frequency 50-60 Hz.
Designed and built entirely by CAME to
meet UNI 8612 safety standards at an
IP 54 level of protection.
Housing in ABS is equipped with vents
to provide internal air circulation.
Guaranteed 12 months, unless
tampered with.
The power supply to the circuit should
be connected to terminals R, S and T
(with three-phase 380V power supply)
or to terminals R and S only (single-
phase 220V power supply), is protected
by a 8A fuse on the main power line.
The ZT4 control panel is factory set for
380V power supply. If the power supply
is 220V, it is necessary to move the
jumper which short-circuit terminals
«380» and «COM» so that it short-
circuits terminals «220» and «COM»
(see pag.12). The Control systems are
powered by low voltage and protected
with a 2A fuse. The total power
consumption of 24 V accessories must
not exceed 20W.
Fixed operating time of 150 seconds.
Safety
Photocells can be connected to obtain:
- Re-opening during the closing cycle (2-
C1);
-4-

GENERAL CHARACTERISTICS

- Re-closing during the opening cycle (2-
CX, see dip 8-9);
- Partial stop , shutdown of moving gate,
with activation of an automatic closing
cycle (2-CX, see dip 8-9);
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must
be actuated to resume movement;
N.B : If an NC safety contact (2-C1, 2-
CX, 1-2) is opened, the LED will flash to
indicate this fact;
- Obstacle presence detection. When the
motor is stopped (gate is closed, open
or half-open after an emercency stop
command), the transmitter and the
control pushbutton will be deactivated if
an obstacle is detected by one of the
safety devices (for example, the
photocells);
- Safety test function. The control unit will
now check the safety system every time
an opening or closing command is given
(see pag.14).
Accessories which can be connected
-Cycle lamp or courtesy light (60 Watt,
see pag.16);
Other functions
- Automatic closing: The automatic
closing timer is automatically activated
at the end of the opening cycle. The
preset, adjustable automatic closing
Tabla de contenido
loading

Este manual también es adecuado para:

Zt4

Tabla de contenido