• connect appliance to mains electricity supply and operate appliance until all solution has been used up
• fill basin 5 times and wait for it to empty
• switch off appliance and disconnect from mains power supply
• remove lid of water supply basin
• unscrew pump filter (Fig. 7)
• clean walls of pump basin, lower part of lid and pump filter with ordinary washing-up liquid using a non-abrasive sponge
• remove transparent panel by removing fixing screws (Fig. 6)
• clean evaporator, transparent panel and scraper with ordinary washing-up liquid, using a non-abrasive sponge. Be careful of
the sharp edges of the scraper. Remove any sediment from the basin under the evaporator
• clean basin under evaporator and spray ring with the same washing-up liquid, using a brush with soft bristles, cleaning the
holes in the spray ring particularly thoroughly
• thoroughly rinse evaporator, scraper, spray ring and basin with cold water
• rinse, dry and refit transparent panel
• rinse and refit lid of pump basin and filter
• turn on the ice-making water supply tap (7 in Fig 3)
• connect the appliance to the mains power supply and operate it for 5 minutes
• prepare to perform the sanitizing operations described in the next paragraph
9.3.b SANITIZING
For sanitizing operations use a 200 mg/l solution of sodium hypochlorite and water or one of the solutions commonly used to
disinfect babies' feeding bottles; in this case, check that the sanitizing product is:
• authorized by your country's Ministry of Health
• suitable for use with food-making machinery
• not harmful to the materials and components of this appliance
For the directions for use and concentrations, please refer to those shown on the packaging and recommended by the
manufacturer. We recommend using the solution at the temperature of 25°C.
Proceed as follows:
• close ice-making water supply tap (7 in Fig. 3) leaving the cooling water (if any) supply tap (8 in Fig. 3) open, and wait for the
water in the pump basin to run out (the ring does not spray water onto the evaporator)
• switch off power supply with the switch (6 in Fig. 3) installed at the installation stage
• remove lid of pump basin
• fill basin with sanitizing solution (Fig. 7)
• close basin and reposition lid
• connect appliance to mains electricity supply and operate appliance until all solution has been used up
• fill basin 5 times and wait for it to empty
• switch off appliance and disconnect from mains power supply
• remove lid of pump basin
• unscrew pump filter (Fig. 7)
• remove transparent panel by removing fixing screws (Fig. 6)
• remove pump filter and transparent panel and immerse in sanitizing solution for at least 30 minutes
• wipe evaporator, spray ring, basin under evaporator and scraper with sanitizing solution using a non-abrasive sponge. Be
careful of the sharp edges of the scraper
• rinse evaporator, scraper, scraper ring and basin under evaporator thoroughly with cold water
• thoroughly rinse, dry and refit transparent panel, checking that it does not interfere with the correct operation of the safety
microswitch
• thoroughly rinse the lower part of the basin lid and refit, tightening the fixing screws
• thoroughly rinse pump filter and replace in its seating
• turn on the ice-making water supply tap (7 in Fig. 3)
• refit front panel and tighten fixing screws
The ice maker can now be reactivated as specified in the previous chapters.
WARNING:
• all the ice produced during the first 30 minutes after cleaning and sanitizing operations must be discarded
• when the appliance is cleaned and sanitized, its bin must also be cleaned and sanitized
You are advised to ask your dealer to draw up a scheduled maintenance contract that will cover the following:
• cleaning the condenser
• cleaning filter on water supply union
• cleaning the ice-tray
• checking the charge of coolant gas
E