11 Battery
The installed battery is designed for a service life of approx. 10 years. The battery and display unit
must not be burnt and must not be disposed of in domestic waste.
To remove the battery, please proceed as follows:
•
Remove the screw on the back of the display unit and open and remove the back of the housing.
•
Disconnect the soldered contacts on the battery with side cutters and remove the battery from
the bracket.
•
Replace the back of the housing on the display unit and tighten the screw.
Dispose of the battery and display unit following
the local environmental guidelines for battery disposal.
12 Technical Data
Operating pressure
Operating/water temperature
Ambient temperature during: operation
Ambient temperature during: storage/transport
Nominal fl ow
PURITY 450 with measuring and display unit
PURITY 450 with distributor head
PURITY 600 with measuring and display unit
PURITY 600 with distributor head
PURITY 1200 with measuring and display unit
PURITY 1200 with distributor head
Empty fi lter cartridge volume
PURITY 450
PURITY 600
PURITY 1200
Weight (dry/wet)
PURITY 450
PURITY 600
PURITY 1200
Dimensions complete system (Width/Depth/Height)
PURITY 450
PURITY 600
PURITY 1200
If BRITA hose sets are used, their bending radii of approx. 130 mm must be added.
Operating position
Inlet connection
Outlet connection
Comparable capacity according to DIN 18879-1:2007
The comparable capacity is a standardised indicator to facilitate comparison of different fi lters. The
comparable capacity is determined under extreme conditions. The usable capacity in practical opera-
tion is higher than the comparable capacity and may vary greatly depending on the usage conditions.
PURITY 450 Quell ST
PURITY 600 Quell ST
PURITY 1200 Quell ST
36
Filter system PURITY Quell ST with fi lter cartridge
2 bar – max. 6.9 bar
4°C to 30°C
10°C to 40°C
–20°C to 50°C
60 l/h at a pressure loss of 0.12 bar
60 l/h at a pressure loss of 0.08 bar
120 l/h at a pressure loss of 0.36 bar
120 l/h at a pressure loss of 0.27 bar
120 l/h at a pressure loss of 0.32 bar
120 l/h at a pressure loss of 0.24 bar
3.9 litres
5.8 litres
10.9 litres
10 kg/12 kg
12 kg/15 kg
18 kg/24 kg
249/212/408 mm (complete system)
249/212/520 mm (complete system)
288/255/550 mm (complete system)
The fi lter system can be operated either
vertically or horizontally.
G1"
G 3/4"
Comparable capacity according to DIN 18879-1:2007
2240 litres
4420 litres
7253 litres