• Overfill protection:
• C-TICK (Australia)
Fully synthetic process connection (enclosure version only) (7ML5610)
• General:
• Marine:
Note: EMC testing was conducted on the CLS100 metal version while mounted in a
metallic vessel and wired using shielded cable. The sensitivity was set by turning
sensitivity potentiometer 2 turns counter-clockwise from the set point.
Safety Guidelines
Warning notices must be observed to ensure personal safety as
well as that of others, and to protect the product and the connected
equipment. Warning notices are accompanied by a clarification of
the level of caution to be observed.
This product can only function properly and safely if it is correctly
transported, stored, installed, set up, operated, and maintained.
WARNING - Parts of the enclosure are non-conducting and may
generate an ignition-capable level of electrostatic charge under
certain extreme conditions. The user should ensure that the
equipment is not installed in a location where it may be subjected
to external conditions which might cause a build up of
electrostatic charge on non-conducting surfaces. Additionally,
cleaning of the equipment should be done only with a damp cloth.
Maintenance
The Pointek CLS100 requires no maintenance or cleaning.
Page EN-4
Pointek CLS100 – QUICK START MANUAL
Ex tb IIIC T107 ºC Db
IP68
-40 ºC Ta +85 ºC
-20 ºC Ta +85 ºC (7ML5610-0...)
DNV #OCP 0017
ABNT NBR IEC 60079-0:2008, ABNT NBR IEC 60079-11:2009
e ABNT NBR IEC 60079-31:2011
WHG (Germany)
CSA, FM
Lloyd's Register of Shipping, categories ENV1, ENV2, and
ENV5
A5E32146158