Safety Features; Circuit Breaker; Maintenance Schedule; Maintenance Procedures - SDMO DX 6000 TE XL C Instrucciones De Instalación Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

5. Safety features

5.1. Oil cut-out
If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.

5.2. Circuit breaker

The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.

6. Maintenance schedule

6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.
6.2. Maintenance table
Operations to be
Component
Check the level
Engine oil
Oil filter
Fuel filter
Air filter
Generating set
Valves *
Injection system*
Battery
* Operation(s) must only be carried out by one of our agents.
The air filter must be cleaned more frequently if the generating set is being used in a dusty environment.
Under occasional heavy use, change the oil at least every year.

7. Maintenance procedures

7.1. Replacing the air filter

Never use petrol or flammable solvents for cleaning the air filter element (risk of fire or explosion).
Important
Remove the wing nut (diag. E - no. 1) from the air filter and recover the washer.
Remove the air filter cover (no. 2, diag. E).
Extract the filter element (diag. E - no. 3) and replace it with a new element.
Refit the air filter cover after cleaning it.
Refit the air filter washer and screw it fully back onto the wing nut.

7.2. Starter battery maintenance

Danger
As the battery is maintenance-free, just check the condition and tightness of the connections and its general cleanliness.
carried out at
Each time it is
whichever
used
deadline is
reached first
Change
Clean
Check
Check
Clean
Clean
Check*
Clean*
Check*
Never leave the battery close to a flame or fire
Use only insulated tools
Never use sulphuric acid or acid water to top up the electrolyte level.
At the end of
3 months or
the:
Every 200
first 50 hours
hours
Every month
6 months or
Every 12
Every 400
months or 1000
hours
hours
Tabla de contenido