Prolonged Disuse; Instructions For Cleaning; Reminders For Cleaning; Instructions For Maintenance - KBS 10516401 Instrucciones Para Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
The yellow indicator light switches on.
Burner extinction
Turn the energy regulator knob to position "
The yellow indicator light switches off.
COOKING
Fill the well.
Turn the knob to position "2".
Adjust the heating according to your cooking requirements.
When the chosen cooking position is other than "5", heating
is intermittent. It switches on and off automatically. The boiling
intensity of the water may vary visibly, but this has no effect on
cooking. When the heating switches off, the yellow indicator
light switches off too.
AT THE END OF SERVICE
Switch the heating off.
Empty the well completely.
Turn the knob to position "0".

14 PROLONGED DISUSE

Before any prolonged disuse of the appliance, proceed as fol-
lows :
Clean the appliance thoroughly.
Rub stainless steel surfaces with a cloth soaked in vaseline
oil to create a protective fi lm.
Leave pot lids open.
Shut off taps and main switches upstream of appliances.
Following prolonged disuse, proceed as follows :
Inspect the appliance thoroughly before using it again.
Allow electric appliances to operate at the lowest temperatu-
re for at least 60 minutes.

INSTRUCTIONS FOR CLEANING

REMINDERS FOR CLEANING

The appliance manufacturer cannot be liable for any da-
mage due to failure to comply with the prescriptions given
below.
Disconnect the appliance electric supply, if present, before
carrying out any operation.
Clean the satin fi nish stainless steel exterior surfaces, the
cooking wells and the surface of the hotplates every day.
At least twice a year, have an authorized technician clean the
internal parts of the appliance.
Do not use direct or high pressure water jets to clean the
appliance.
Do not use corrosive products to clean the fl oor beneath the
appliance.
SATIN FINISH STAINLESS STEEL SURFACES
Clean the surfaces with a cloth or sponge using water and
proprietary non-abrasive detergents. Follow the direction of
the satin fi nish lines. Rinse repeatedly and dry thoroughly.
Do not use pan scourers or other iron items.
Do not use chemical products containing chlorine.
Do not use sharp objects which might scratch and damage
the surfaces.
COOKING WELLS
Clean the wells by bringing the water to the boil, with the ad-
dition of grease remover detergent if necessary.
Remove any limescale deposits with a proprietary limescale
remover.
".

REMINDERS FOR THE MAINTENANCE TECHNICIAN

The appliance manufacturer cannot be liable for any da-
mage due to failure to comply with the prescriptions given
below.
Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualifi ed technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions in this manual.
Identify the specifi c appliance model. The model number is
detailed on the packing and on the appliance dataplate.
The appliance must be installed in a well-ventilated room.
Do not obstruct any air vents or drains present on the ap-
pliance.
Do not tamper with appliance components.

15 CONVERSION TO A DIFFERENT TYPE OF GAS

See Chapter " Instructions for installation ".

16 COMMISSIONING

Following installation, conversion to a different type of gas or
any maintenance operations, check appliance operation. In the
event of any malfunction, consult the next Paragraph "Trouble-
shooting".
16.1 GAS APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check :
the gas supply pressure ( see next Paragraph ).
the correct ignition of the burners and the effectiveness of the
fumes removal system.
16.1.1
To measure the gas supply pressure use a manometer with a
minimum defi nition of 0.1 mbar.
Remove the control panel.
Remove the screw from on pressure test point PP and con-
nect the manometer to the test point.
Make the measurement with the appliance in operation.
IMPORTANT ! If the gas supply pressure is not within the limits
( Min. - Max ) indicated in Table T2 , cease operation of the
appliance and contact the gas utility company.
Disconnect the manometer and retighten the retaining screw
on the pressure connection.
16.2 ELECTRICAL APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check :
the current values of each phase.
the correct operation of the heating elements.

INSTRUCTIONS FOR MAINTENANCE

CHECKING THE GAS SUPPLY PRESSURE
33
Tabla de contenido

Solución de problemas

loading

Tabla de contenido