FireClass FC500PSTN Manual De Instalación página 10

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Functioning of the Channel Telephone Dialler When a valid event occurs:
1. The Telecom Module will use the telephone line to which it is connected (termi-
nals L.E.), isolating all telephone devices connected downstream (terminals L.I.).
2. If Enabled , the Telecom Module controls whether it could obtain a Dialling Tone, if it
could obtain it move to the next step, otherwise it will consider the phone call to have
failed, hook up and revert to step no. 1.
3. The Telecom Module dials the first Telephone Number which has been program-
med for the event which has occurred.
4. If the Start playing after Selection option has been selected, the Telecom Mo-
dule will move on directly to the next step, otherwise,
if the Start playing after Voice-on-line option has been selected, the Telecom Module
will wait for the answer from the dialled number for 30 seconds, if it does not obtain it, it
will consider the phone call to have failed, hook up and revert to step no. 1, otherwise,
if the Start playing after Delay option has been selected, the Telecom Module will wait
for the Delay which has been programmed before moving to the next step.
5. The Telecom Module displays the Header Message, then the Status Message, de-
pending on the kind of event which has given rise to the call, then the programmed
General Message programmed for the event which has given rise to the call.
6. If the Confirm Call Result option is disenabled, the Telecom Module will give again the
sequence of messages according to the number of Repetitions it has been programmed
for, then it will consider the phone call to have failed, hook up and revert to step no. 1;
If the Confirm Call Result option is enabled the Telecom Module will hook up as
*
soon as the
key is pressed on the called telephone line, will consider the phone
call to have gone through and will revert to step no. 1; if the
ter the number of programmed Repetitions, it will hook up, consider the phone call to
have failed and revert to step no. 1.
If the Call all voice messages numbers option is enabled, the Telecom Module will call
all programmed numbers for the event which has occurred, until all phone calls fully suc-
ceed according to the number of Call Attempts which have been programmed.
If the Call all voice messages numbers option is disenabled, the Telecom Module
will interrupt the calls as soon as it succeeds finishing its calls.
n Telemonitoring
The Telecom Module supplements a Digital Communicator which allows the imple-
mentation of the Telemonitoring function in the FC500 series control panels. This
function allows organizations which are equipped with suitable devices, to "monitor"
from a distance the status of the fire detection system.
EVENT
CL.
Software Zone Alarm
1
Conventional Zone
1
Alarm
Control Panel Alarm
1
Software Zone Warning
1
Control Panel Warning
1
Software Zone Fault
3
Conventional Zone
3
Fault
Control Panel Fault
3
Software Zone Test
6
Control Panel Test
6
Loop Fault*
3
Network fault (230 V)
3
Low Battery
3
Missing Battery
3
Earth fault
3
Control Panel Output
3
Fault**
Network fault (RS485)
7
***
Control Panel
7
Pre-Alarm
Software Zone
7
Pre-Alarm
Conventional Zone
7
Pre-Alarm
Table 2 Factory Event Codes: *) Open or short loop. **) NAC or OS Outputs, open or short. ***)....
10
*
key is not pressed af-
CONTACT ID
COD.
GROUP
10
Panel no.
10
Panel no.
10
Panel no.
200
Panel no.
200
Panel no.
00
Panel no.
00
Panel no.
00
Panel no.
04
Panel no.
04
Panel no.
31
Panel no.
01
Panel no.
02
Panel no.
11
Panel no.
10
Panel no.
20
Panel no.
51
Panel no.
118
Panel no.
118
Panel no.
118
Panel no.
The Telemonitoring function sends certain Event Codes, to a series of programma-
ble Telephone Numbers, whenever specific Events occur.
To send these data, certain Protocols are used which establish how these should be
formatted and the data sent.
The Telecom Module supports the two most widespread communication protocols in
the field of the telemonitoring: Contact ID and SIA.
Events The events which could send an event code are the same as those of the
Telephone Dialler.
Telephone Numbers For the Telephone Numbers which could be called by the
Telemonitoring function, the same remarks shall apply as those made for the fun-
ction of Channel Telephone Dialler.
Contact ID The Contact ID protocol relays the following information (see the
CONTACT ID columns in Table 2).
Ø Customer Code: 4 digits from 0 to F for the identification of the system; the Tele-
com Module allows the definition of a Client Code for each Telephone number.
Ø Qualifier: 1 = a new event; 3 = re-enablement of an event.
Ø Class Code (column CL.): identify the type of event (Alarm, Fault, etc.); in the following
table the pre-defined Class Codes are shown; the Class Codes could be changed.
Ø Event Code (column COD.) : identifies the event; in the following table the
pre-defined Event Codes are shown; the Event Codes could be changed.
Ø Group number (column GROUP) : 2 digits for the identification of the control panel.
Ø Zone number (column ZONE): 3 digits of the Software Zone; 000 for Control Pa-
nel Events; 999 for the Conventional Zone.
SIA The SIA protocol relays the following information (see the SIA columns in Table 2).
Ø Client Code: 4 digits from 0 to 9 for the identification of the system; the Telecom
Module allows the definition of a Client Code for each Telephone number.
Ø Function Code: N = New Event; O = Re-enabling Event .
Ø Date: month, day and year in which the event has occurred.
Ø Time: hour, minutes and seconds in which the event has occurred.
Ø Event Type (TYPE column): it identifies the event; the following table shows the
pre-determined Event Types; the Event Types could be changed.
Ø Peripheral ID (PI column) : 2 digits for the identification of the control panel.
Ø Area ID (RI column) : 4 digits for the identification of the Software Zone; 0000 for
Control panel Events; 9999 for the Conventional Zone.
ZONES
TYPE
zone no.
FA
999
FA
000
FA
zone no.
FS
000
FS
zone no.
FT
999
FT
000
FT
zone no.
FX
000
FX
000
FT
000
AT
000
YT
000
YM
000
FT
000
YA
000
NT
000
FG
zone no.
FG
999
FG
SIA
PI
RI
Panel no.
zone no.
Panel no.
9999
Panel no.
0000
Panel no.
zone no.
Panel no.
0000
Panel no.
zone no.
Panel no.
9999
Panel no.
0000
Panel no.
zone no.
Panel no.
0000
Panel no.
0000
Panel no.
0000
Panel no.
0000
Panel no.
0000
Panel no.
0000
Panel no.
0000
Panel no.
0000
Panel no.
0000
Panel no.
zone no.
Panel no.
9999
Telecom Module FC500PSTN
Tabla de contenido
loading

Tabla de contenido