Product Safety Information
Intended Use:
These Air Sump Pumps are designed for pumping non-hazardous liquids that are
compatible with pump components.
For additional information refer to Air Sump Pump Product Safety Information Manual
Form 16576597.
Manuals can be downloaded from www.irtools.com.
Product Specifications
Height
Model
mm
S35
485
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install
a properly sized Safety Air Fuseupstream of hose and use an anti-whip device across any
hose coupling without internal shut-off, to preventhose whipping if a hose fails or coupling
disconnects. See drawing 16586281 and table on page 2. Maintenance frequency is shown in
circular arrow and defined as h=hours, d=days, and m=months. Items identified as:
1. Air filter
2. Regulator
3. Lubricator
4. Emergency shut-off valve
5. Hose diameter
6. Air Inlet - Thread size
7. Safety air fuse
Adjustments
Air Strainer
Periodically, clean the Air Strainer Screen as follows:
1.
Shut off the air supply to the pump.
2.
Unscrew the Air Strainer Cap and remove the Air Strainer Screen.
3.
Clean the Screen in a suitable cleaning solution.
91358614_ed5
Mass
Discharge Size Air Inlet Size Exhaust Size
kg
mm
34
50
mm
25
8.
Oil
9.
Oil - If Lubricator (3) is not used
10. Oil - Fill oil chamber before initial start
11. Grease - In fitting
12. Air Exhaust - Thread size
13. Pump Discharge - Thread size
EN
Air Cons.
mm
m
/min
3
32
3.9
EN-1