(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown
in Table 3.
Table 3 Charging time (At 20°C)
Charger
UC14YFA
Battery
EB14B
Approx. 50 min.
EB1820L
EB1424
Approx. 60 min.
EB1824L
EB1426H Approx. 60 min.
EB1826HL
EB1430H Approx. 70 min.
EB1830HL
EB1433X Approx. 75 min.
EB1833X
NOTE
The charging time may vary according to temperature
and power source voltage.
4. Disconnect the charger's power cord from the
receptacle
5. Hold the charger firmly and pull out the battery
NOTE
After operation, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might
be low when using them the first and second time.
This is a temporary phenomenon, and normal time
required for recharging will be restored by recharging
the batteries 2 – 3 times.
How to make the batteries perform longer.
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the battery
and recharge it after it has cooled for a while.
CAUTION
If the battery is charged while it is heated because it
has been left for a long time in a location subject to
direct sunlight or because the batetery has just been
used, the pilot lamp of the charger lights up green. In
such a case, first let the battery cool, then start
charging.
UC18YRL
UC24YFA
UC18YFL
Approx. 50 min. Approx. 30 min.
Approx. 35 min.
Approx. 60 min.
Approx. 40 min.
Approx. 70 min. Approx. 45 min.
Approx. 75 min. Approx. 50 min.
When the pilot lamp flickers in red (at 0.2-second
intervals), check for and take out any foreign objects
in the charger's battery installation hole. If there are
no foreign objects, it is probable that the battery or
charger is malfunctioning. Take it to your authorized
Service Center.
Since the built-in micro computer takes about 3
seconds to confirm that the battery being charged
with UC14YFA/UC24YFA/UC18YRL/UC18YFL is taken
out, wait for a minimum of 3 seconds before
reinserting it to continue charging. If the battery is
reinserted within 3 seconds, the battery may not be
properly charged.

PRIOR TO OPERATION

1. Setting up and checking the work environment
Check if the work environment is suitable by following
the precautions.
HOW TO USE
1. Confirm the cap position (see Fig. 4)
The three modes of screwdriver, drill and impact drill
can be switched by the position of the cap in this unit.
(1) When using this unit as a screwdriver, line up the one
of the numbers "1, 4, 7 ... 22" on the cap, or the black
dots, with the triangle mark on the outer body.
(2) When using this unit as a drill, align the cap drill mark
"
" with the triangle mark on the outer body.
(3) When using this unit as an impact drill, align the cap
hammer mark " " with the triangle mark on the
outer body.
CAUTION
The cap cannot be set between the numerals "1, 4, 7
... 22" or the black dots.
Do not use with the cap numeral between "22" and
the black line at the middle of the drill mark. Doing so
may cause damage (See Fig. 5).
2. Tightening torque adjustment
(1) Tightening torque
Tightening torque should correspond in its intensity
to the screw diameter. When too strong torque is
used, the screw head may be broken or be injured.
Be sure to adjust the cap position according to the
screw diameter.
(2) Tightening torque indication
The tightening torque differs depending on the type
of screw and the material being tightened.
The unit indicates the tightening torque with the
numbers "1, 4, 7 ... 22" on the cap, and the black
dots. The tightening toque at position "1" is the
weakest and the torque is strongest at the highest
number (See Fig. 4).
(3) Adjusting the tightening torque
Rotate the cap and line up the numbers "1, 4, 7 ... 22"
on the cap, or the black dots, with the triangle mark
on the outer body. Adjust the cap in the weak or the
strong torque direction according to the torque you
need.
CAUTION
The motor rotation may be locked to cease while the
unit is used as drill. While operating the impact driver
drill, take care not to lock the motor.
Too long hammering may cause the screw broken
due to excessive tightening.
English