4.3
Compressed air connection
• Push the compressed air tube (21) onto the tube connection
point (11) as far as it will go� In doing so there will be a slight
resistance to overcome�
• To connect to the compressed air system, select the relevant
tube coupling from the supplied set and attach this to the other
end of the tube�
• Attach to the compressed air network�
4.4
Electrical connection
Ensure that the voltage information on the type plate and the
mains voltage are compatible.
• Plug the mains cable (22) into the socket (3)�
• Plug in the mains cable�
4.5
Connection to suction device
• Plug the suction tube from the extraction unit to the suction
pipe (18)�
• For suction devices with automatic activation: connect the mains
plug from the sandblasting unit into the user socket on the suc-
tion device�
4.6
Adjusting the Operating Pressure
• Activate the foot switch�
• Set the sandblasting pressure (1 - 6 bar /14�5 - 87 psi) at the
pressure regulator (2)�
The amount of pressure will be shown on the pressure
gauge (6)�
4.7
Filling the Sandblasting Tanks
Attention: Never press the foot switch during filling.
Even though the manometer may indicate pressure, the sand-
blasting tanks are only under pressure if the foot switch is
engaged.
• Add abrasive up to the maximum fill level (the point where the
tank jacket thickens just below the thread)�
• Reinstall the tank cover�
Before closing the tank, be sure to clean the threads in the
cover and the tank to remove any abrasive residue.
Caution: Do not tilt the tank lid when unscrewing.
Always use only clean, dry abrasive of the appropriate grain size (refer to the accessories)�
The sandblasting unit is now operational.