Health Zenith SL-5525 Manual De Instrucciones página 3

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has about 1
period before it will detect motion. When first
turned on, wait about 1
❒ Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum Range
The detector is most sensitive to motion across its field
of view.
Motion
Sensor
Least Sensitive
595-5295-11
1
/
minutes warm up
2
1
/
minutes.
2
RANGE
MIN
MAX
180°
70 ft.
(21 m)
Maximum
Coverage Angle
Motion
Most Sensitive
❒ Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected).
Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 1" (2.5 cm)
away from the lamp.
❒ Adjust the RANGE as
needed. RANGE set too high
may increase false triggering.
❒ Secure the sensor head
by tightening the clamp
screw. Do not overtighten
the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up to 250 Watts Maximum In-
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . T3, 250W (or less) halogen
DESA Specialty Products™ reserves the right to discon-
tinue products and to change specifications at any time
without incurring any obligation to incorporate new fea-
tures in products previously sold.
3
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature].
candescent.
MODE
120 VAC
Tabla de contenido
loading

Tabla de contenido