AL series
instruction
manual
•REPLACE BATTERY
This alarm indicates that the battery must be replaced. After
the replacement, it is necessary to set the time again (see
PROBLEMA
The valve does not regenerate automatically - make sure that the equipment is connected to power supply (fig. 9, A, B)
The valve regenerates at the wrong time
Water from the brine is not sucked,
the water softener does not consume salt
The brine overfills
If the excessive filling occurs during
the regeneration:
If the excessive filling occurs when the
machine is operating:
Water softener salt consumption
is higher or lower than expected
After regeneration, water is not softened
The water softener dispenses salt water
22
paragraph 4.2).
14) PROBLEMS AND SOLUTIONS
RISOLUZIONE
and that the electric card connector is inserted (fig. 7, C)
- check the settings (see chapter 5, "SETTING THE TIMER")
- check the current time and regeneration time settings
(see paragraph 4.2 and 5.3)
- make sure that the water system pressure is at least 2 bar
- check that the drain pipe is not blocked or flattened (fig. 5, A)
- clean the injector (fig. 10, B) (see paragraph 9.1)
- make sure that there is no air intake where there are the quick joints (fig. 8, A)
- make sure the drain pipe isn't blocked or flattened (fig. 5, A)
- make sure that there is no air intake where there are the quick joints (fig. 8, A)
- clean the injector (fig. 10, B) (see paragraph 9.1)
- check that operating pressure is at least 2 bar
- make sure the selected model is correct and, if the filling time was
customized, make sure that the duration of step B7 falls between
the range values (see paragraph 5.5)
- make sure there are no leaks between upper part and tank (fig. 1, C and D)
- make sure water does not seep in the brine tank from the brine pipe (fig. 8, A)
- make sure the selected model is correct and, if the filling time was
customized, make sure that the duration of step B7 falls between the
range values (see paragraph 5.5)
- check the power supply and the valve settings (see chapter 5)
- check that there is salt in the brine tank (fig. 8)
- check that the mixer screw is tightened correctly (fig. 3, M) (see chapter 8)
- his problem may be caused by a lack of hydric pressure during the
regeneration, which prevented a correct rinsing cycle.
Start the resin rinse program (see paragraph 7.3)
ENGLISH
Instruction manual AL series