8. Hose drainage
In the case of very damp rooms, it is often
more reasonable for the water not to be col-
lected in the water tank, but to be dis-
charged directly through a hose.
WARNING! During hose drainage, the de-
vice runs in continuous mode. This means
that the water collected must be able to
drain reliably, otherwise puddles will form
on the floor.
1. Figure C: use a screwdriver to remove
the fastener 21 on the rear.
2. Remove the plug 23.
3. Figure C: place the hose 22 included
in the box over the opening.
4. Place the device in a position where
the end of the hose is over a drain. It is
essential here that the open end of the
hose is lower down than the drain out-
let on the device (i.e. the hose must run
at a downward angle).
5. Switch the device on as described
above and select a mode.
6. If you wish to drain into the water
tank|5 again, switch the device off, re-
move the hose 22, and replace the
plug 23 firmly over the opening.
9. Cleaning and
replacing the filter
The performance of the device also depends
on the cleanliness of the filter.
• The carbon filter 25 should be cleaned
every 2 weeks and replaced every
6|months. Clean the filter by brushing
or vacuum suction.
• The normal plastic filter 24 should be
washed every 2 weeks.
52 GB
1. Switch the device off and pull out the
mains plug 10.
2. Figure D: reach into the upper open-
ing of the grid 8 and pull it off.
3. Rotate grid 8 and press, if necessary
with both thumbs, in the middle of the
grid.
4. The plastic filter 24 and the carbon fil-
ter 25 come loose from the grid. Re-
move them from the grid 8.
5. Rinse out both filters with lukewarm wa-
ter. (The carbon filter 25 should be re-
placed after approx. 6 months.)
6. Allow both filters to dry completely.
7. Place the filters into the grid 8.
8. Place the grid onto the device.
NOTE: new carbon filters are available in
almost all household goods shops. The pads
just need to be cut to size.
10. Cleaning
Clean the device prior to its first use!
DANGER! Risk of electric
shock!
• Pull the mains plug 10 out of the
grounded power socket before you
clean the device.
• The device, the power cable and the
mains plug 10 must not be immersed in
water or any other liquids.
WARNING! Risk of material dam-
age! Do not use any astringent or abrasive
cleaning agents.
• Wipe the housing and the power ca-
ble|10 with a damp cloth if necessary.
• Remove the water tank 5, pour out the
water, and dry the tank well inside and
outside before re-inserting it into the de-
vice.