Problems And Solutions; Technical Features - Chicco SterilNatural 3in1 Manual Del Usuario

Esterilizador a vapor modular eléctrico
Ocultar thumbs Ver también para SterilNatural 3in1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
least once a week, or each time that deposits of limescale are
found on the heating plate/container (e) or on the detachable
base for microwaves.
1. Pour 200 ml of a solution composed of equal parts of white
wine vinegar and water into the heating plate/container (e) or
detachable base for microwaves (i).
2. Leave it to work until the limescale has dissolved (approxi-
mately one night). Never switch the steriliser on when the con-
tainer is being soaked in the water-white vinegar solution.
3. Empty out the heating plate/container (e) or detachable base
for microwaves (i).
4. Remove any residue with a soft cloth and rinse several times,
pouring 200 ml of drinkable tap water into the heating plate/
container (e) or detachable base for microwaves (i) and empty
out. Finally, dry the appliance carefully with a soft dry cloth be-
fore using it again.
WARNING: do not place the appliance under running
water in its FULL SIZE and COMPACT configurations.

PROBLEMS AND SOLUTIONS

Problem
The steriliser is noisy.
The steriliser does not switch on.
The feeding bottles are stained at the end
of the sterilisation cycle.
The symbol "HT" appears on the display
The symbol "FU" appears on the display
N.B. IMPORTANT: If none of the solutions indicated above solves the problem, please contact Artsana Customer Service.

TECHNICAL FEATURES

Codes 00007391000000
Model: 06782
Power: 220-240V ~ 50/60Hz
Power: 600 W
Made in China
Possible Cause
Excessive limescale deposit on the heating
plate/container (e).
There is no power.
The plug is not connected properly.
The main ON/OFF switch (h) is in the 0
(OFF) position.
Excessive limescale deposit on the heating
plate/container (e) or detachable base for
microwaves (i).
Not enough water inside the heating plate/
container (e).
The thermal fuse is broken
15
Solution
Clean the heating plate/container (e) by
removing the limescale with white wine
vinegard (see the section "Removing
limescale").
Check that there is power in the mains.
Verify that the plug has been connected
properly and that it is in good condition.
Move the main ON/OFF switch (h) to I (ON).
Clean the heating plate/container (e) by
removing the limescale with white wine
vinegar (see the section "Removing lime-
scale").
Place the correct quantity of water inside
the heating plate/container (e) and restart
the sterilisation cycle (please see the
section "how to prepare and use the ap-
pliance").
The appliance needs to be repaired. Only
contact a qualified technician or Artsana
S.p.a.