The generator sets to be stored for over 30 days must undergo special operations to en-
sure their correct storage
1-
To protect the motor, we recommend the use of Briggs & Stratton petrol additive, Refe-
rence No. 5041(see figure I), available for all approved distributors. Add the additive in the
fuel tank or in a storage tank. Run the motor for a few moments to circulate the additive in
the carburettor. The motor and the fuel can then be stored for not more than 24 months
2-
While the motor is still hot, drain the oil from the casing. Replace it with new oil of a
.
suitable grade
3-
Remove the spark plug and pour approximately 15 ml of motor oil into the cylinder.
Reassemble the spark plug and run the motor to distribute the oil
4-
Remove dirt from the cylinders, cylinder head blades, cooling casing, wheel grille and
.
silencer
5-
Clean the generator set
6-
Seal the AC generator air inlet and outlets with plastic adhesive tape.
7-
Store the generator set in a clean and dry place