Repairs - Wilo Vardo WEEDLESS-F Instrucciones De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 904
en
7
6
5
Fig. 12: Oil change
9.6

Repairs

256
Maintenance and repair
1
1
Connection piece for compressed air
2
Drain hose
2
3
Oil drain line with dummy plug
3
4
Collector tank
4
5
Gear
6
Oil level screw
7
Oil filler opening
Mixer has been decommissioned.
Drive unit has cooled, been cleaned and, if necessary, disinfected.
Work area has been prepared.
Protective equipment has been put on.
Tools/aids to hand:
- Drain hose, length approx. 0.5 m (20 in)
- Compressed air hose, inside diameter 10 mm (0.5 in)
- Compressed air, max. 0.8 bar (11.5 psi)
- Collector tank of sufficient volume
- Funnel
Manufacturer's safety instructions have been read and implemented!
1. Remove the screw plug from the oil filler opening.
2. Screw the connection piece into the oil filler opening.
3. Connect the compressed air to the connection piece.
4. Remove the dummy plug from the oil drain line.
5. Attach the drain hose to the oil drain line.
6. Place the drain hose in the collector tank.
7. Slowly release the compressed air. Max. pressure: 0.8 bar (11.5 psi)
8. Drain the gear.
⇒ Ignore any minimal residues.
⇒ If significant residues remain in the gear, rinse the gear repeatedly with clean-
ing oil.
9. Inspect the oil in the collector tank:
⇒ If the oil is heavily contaminated, rinse the gear repeatedly with cleaning oil.
⇒ If the oil contains metal chips, notify customer service!
10.Remove the drain hose from the oil drain line.
11.Seal the oil drain line with the dummy plug.
12.Detach the compressed air and connection piece from the oil filler opening.
13.Remove the oil level screw to allow venting.
14.Pour new oil into the oil filler opening using a filling funnel. NOTICE! Consult the
motor's rating plate for information on oil type and quantity.
15.Screw in the oil level screw and the oil filler opening's screw plug.
16.Check all screw plugs for impermeability.
▶ Oil change is complete. Recommission the mixer.
DANGER
Danger from fluids hazardous to health!
Risk of fatal injury if the mixer is used in fluids hazardous to health.
• Decontaminate the mixer after dismantling and before carrying out any other
work.
• Observe the specifications provided by work regulations. The operator must
make sure that personnel have received and read work regulations.
WILO GVA GmbH 2019-02