PBT 600 – Battery Conductance Testeur
● Normally, cranking voltage value lower than 9.6V is regarded as
abnormal, higher than 9.6V is OK.Test result includes actual
cranking voltage, actual cranking amps, and actual cranking time.
● When cranking test is abnormal, battery test result will also be
displayed at the same time.See right side image:
After testing finished, do not shut down the engine, press OK key to enter Charging Test.
11. Charging System and Rectifier Diode Test
● When enter the charging test, tester will prompt "Charging Test?" Press OK key to start
the charging test.
NOTE: Do not shut down the engine during the test.All
electrical appliance and device are in OFF state.Turn on/off
any electrical appliance in the vehicle during the test will
affect the accuracy of the test result.
● Tester will do the following tests in a sequence:For ripple test,
tester will display the real time ripple and meanwhile, shows ripple
volt and charging volt values at the bottom line.
● After the ripple test, tester will automatically start the loaded
voltage test.
● Loaded Volt Test takes approx. 3 seconds, then it hints "Step on
accelerator to increase engine rotating speed".Operate accordingly
to increase the engine rotating speed to 3000turns or above, and
keep for 5 seconds.
● Tester starts the charging volt test after increase rev detected.
The result displays the effective charging volts, ripple test result
and charging test result.
● If no increase rev detected, it shall be the fault of generator
regulator or connection with battery failed.Tester will try 3 times to
further detect, if still failed, it will skip the increase rev detect and
the test result displays "No Volt Output". Check the connection
between generator and battery, then retest.
● Charging Test Result:
1. Charging Volt: Normal. The generator output normal, no problem detected.
UK - 9