Circulation pump C090
Typical applications
These centrifugal pumps are ideal for instal-
lation in recreation vehicles and buses etc for
use as circulating pumps e g when cooling
fresh water and for water in heating systems.
All-round pumps that can be used wherever
self-priming is not essential.
Technical description
Body:
PA66
Impeller:
PA66
Shaft:
Stainless steel
Shaft seal:
Mechanical seal
Motor:
Permanent magnet motor
12/24 V
Connection:
38 mm (1.1/2") hose
O-ring:
EPDM
Radio distur-
bance shielded: EN55014
Type designation
Pumptype
C090P5-1 12 V
C090P5-1 24 V
Pressure and capacity data
Based on water at 20°C/68°F
Spare parts
(see p 16-17)
Original instructions
Order No
Connection
10-24190-1
38 mm (1.1/2")
10-24190-2
38 mm (1.1/2")
(see p 15)
Installation recommendations
The C0-series pumps are normal-priming
centrifugal pumps and should be mounted in
a manner that ensures that they are always
flooded or else be primed before being
switched on.
Note! The pump must never be run dry.
The direction of rotation of the pump is clock-
wise, viwed from the front towards the body
(see rotation arrow).
The motors are designed for continuous
operation in liquid temperature range of -30°C
– +100°C (-22°F – +212°F).
The pumps can be installed horizontally or
vertically. When installed vertically the motor
should be above the pump body. To avoid
air-locks when mounted horizontally, the body
should be turned in such a way that the outlet
is directed upwards or is placed on the upper
side of the pump body. The pumps should not
be used for sea-water or other heavy soiled
liquids.
Do not high pressure wash.
Ambient temperature:
Max system pressure:
Electrical installation
Connect red lead to positive (+) terminal and
black lead to negative (-) terminal (or earth).
> English
-30°C – +70°C
(-22°F – +158°F)
2 bar.
5