Reset And Factory Settings; General System Reset; Factory Settings; Restoring The Factory Settings - DAB E.SYBOX MINI 3 Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 358
Automatic resets of error conditions
Display
Description
indication
Blockage due to water
BL
lack
Blockage due to line
PB
voltage outside specifi-
cations
Blockage due to
OT
overheating of the
power stages
Blockage due to motor
OC
overload
Table 9: Self-reset of blockages

7 - RESET AND FACTORY SETTINGS

7.1 - General system reset

To reset the system, hold down the 4 keys simultaneously for 2 sec. This
operation is the same as disconnecting the power, waiting for it to close
down completely and supplying power again. The reset does not delete
the settings saved by the user.
Automatic reset sequence
- One attempt every 10 minutes for a
total of 6 attempts.
- One attempt every hour for a total of
24 attempts
- One attempt every 24 hours for a to-
tal of 30 attempts.
- It is reset when it returns to a specific
voltage.
- It is reset when the temperature of
the power stages returns within the
specifications.
- One attempt every 10 minutes for a
total of 6 attempts.
- One attempt every hour for a total of
24 attempts.
- One attempt every 24 hours for a to-
tal of 30 attempts.

7.2 - Factory settings

The device leaves the factory with a series of preset parameters which
may be changed according to the user's requirements. Each change of the
settings is automatically saved in the memory and, if desired, it is always
possible to restore the factory conditions (see Restoring the factory set-
tings par par 7.3 - Restoring the factory settings).

7.3 - Restoring the factory settings

To restore the factory values, switch off the device, wait until the display
has switched off completely, press and hold down the "SET" and "+" keys
and turn on the power; release the two keys only when the letters "EE"
appear.
This restores the factory settings (a message and a rereading on EE-
PROM of the factory settings permanently saved in the FLASH memory).
Once all the parameters have been set, the device returns to normal op-
eration.
NOTE: Once the factory values have been restored it will be necessary to
reset all the parameters that characterise the system (gains, setpoint pres-
sure, etc.) as at the first installation.
Factory settings
Identifying
Description
code
BK
Display brightness
TK
Backlight lighting T
LA
Language
SP
Setpoint pressure [bar]
Revs per minute in manual
RI
mode [rpm]
OD
Type of plant
Pressure decrease to
RP
restart [bar]
ENGLISH
Value
Installation Memo
³
e.sybox mini
80%
2 min
ENG
2,7
3200
1 (Rigid)
0,3
GB
64
Tabla de contenido
loading

Tabla de contenido