12.9 Sensor menu
In addition to the chronothermostat's internal sensor, it is possible to connect to terminals 13 and 14 «AUX 1» (see wire
diagrams in section ."6.4 Electrical connections") an additional (optional) sensor that can be adjusted to read the temperature
in different ways.
•
Following the path of the button Menu -> CONFIG SEt -> SENSOR SEt, press the OK button to enter the menu. The
selectable functions are as follows:
SENSOR NO
The additional sensor is not read and is disabled (factory setting when first switched on).
REMOTE SENSOR
Measures the temperature of an environment instead of the chronothermostat's internal sensor.
FLOOR SENSOR
Measures the temperature of the floor and switches off the connected load if a determined set
threshold is exceeded. Environmental temperature control is managed by the chronothermostat's
internal sensor.
EXTERNAL SENSOR Measures the temperature outside of the house without affecting the temperature control of the
indoor environments.
66