Trouble Shooting
1.
Motor starter cuts out vacuum pump:
1.1 Check that incoming voltage and frequency corresponds with the motor data plate.
1.2 Check the connections on the motor terminal block.
1.3 Incorrect setting on the motor starter.
1.4 Motor starter trips too fast.
Solution: Use a motor starter with a time delay trip (version as per IEC 947-4).
1.5 The vacuum pump or the lubricating oil is too cold.
1.6 The viscosity of lubricant is too high.
1.7 Oil mist eliminator elements are blocked or contaminated.
1.8 Back pressure on the exhaust pipework is excessive.
2.
Insufficient suction capacity:
2.1 Cylinder mesh of the 2.Suction of the VFS 220.80 is obscured.
2.2 Suction pipe work is too long or too small.
3.
Vacuum pump does not reach ultimate vacuum:
3.1 Check for leaks on the suction side of the pump or at the system.
3.2 Viscosity of lubricant incorrect.
4.
Vacuum pump operates at an abnormally high temperature:
4.1 Ambient or suction temperature too high.
4.2 Cooling air flow is restricted.
4.3 Problem as per 1.6, 1.7 and 1.8.
5.
Exhausted air contains visible oil mist:
5.1 Oil separator elements are fitted incorrectly.
5.2 Incorrect oil brand is used.
5.3 Problem as per 1.7, 1.8, 4.1 and 4.2.
6.
Unit emits abnormal noise:
Note: A knocking noise from the rotor blades is normal when cold starting as long as it disappears within two minutes with increasing operating
temperature.
6.1 The coupling rubbers are worn (see under "servicing").
6.2 The pump cylinder is worn. Solution: send your complete unit off for repair to the supplier or approved service agent.
6.3 Blades are damaged.
6.4 Problem as per 1.5 and 1.6.
7.
Water in lubricant i.e. Emulsification:
7.1 Pump pulls in water because of the application.
Solution: Fit water separators on to the vacuum side.
7.2 Unit handles more water vapour than the gas ballast is designed for.
Solution: Consult supplier for the provision of an increased gas ballast capability.
7.3 Pump operates only for a short time and does not reach normal operating temperature.
Solution: Run the pump with closed suction until the oil has been cleaned.
Appendix:
Repair on Site: For all repairs on site an electrician must disconnect the motor so that an accidental start of the unit cannot happen.
All engineers are recommended to consult the
original manufacturer or one of the subsidiaries,
agents or service agents. The address of the
closest repair workshop can be obtained from
the manufacturer on application.
After a repair or before re-installation follow the
instructions as shown under the headings Instal-
lation and Initial Operation.
Lifting and Transport: To lift and transport the
vacuum pump the eye bolts on the pump
used
. For it must be screwed 3 eye bolts M 12 in
the planned tapped holes (X) (see pictures
and
).
The weight of the pumps are shown in the
accompanying table.
Storage: VFS units must be stored in dry ambi-
ent conditions with normal humidity. If a pump
needs to be stocked for a period longer than 3
months we would recommend using an anti-
corrosion oil rather than the normal lubricant.
Disposal: The wearing parts (as listed in the
spare parts lists) should be disposed of with due
regard to health and safety regulations.
Spare parts lists:
E 206
E 207
VFS
Capacity
Ultimate vacuum
must be
Motor version
Motor rating
Current drawn
Speed
Average noise level
Noise level (max.)
VFS 201
Weight
VFS 220.80
Oil capacity
50 Hz
m³/h
60 Hz
50 Hz
mbar
60 Hz
50 Hz
3 ~
60 Hz
50 Hz
kW
60 Hz
50 Hz
A
60 Hz
50 Hz
-1
min
60 Hz
50 Hz
dB(A)
60 Hz
50 Hz
dB(A)
60 Hz
kg
l
100 l/ hr cooling water at 15°C inlet temperature
201
220.80
Stage I
Stage II
200
220
225
0,5
0,5
230/400V ± 10%
220/380V
5,5
6,5
19,7/11,4
23,4/13,5
1450
1740
68
73
71
75
72
77
75
79
160
180
8
80
0,8
1,0
/ PM6