Operation of a TBH Extraction and Filter System
Run/Standby Jumper
The Run/Standby jumper is used to define the initial mode of the extraction and filter
systems. It is designed as a bridge in the plug between pins 09 and 10 of the interface
connection cable on the side of the extraction and filter system. In order to exclude errors in
the operation of the system, it is not recommended to realize the jumper on the terminal strip
of the target system.
If it is desired that the extraction and filter system starts directly in run mode after switching
on at the mains switch, i.e. starts immediately with extracting, then pins 09 and 10 are not
connected. If it is desired that the extraction and filter system starts directly in standby mode
after switching on at the mains switch, i.e. does not start with extracting, then pins 09 and 10
must be connected.
94