System Startup - PNI Safe House PG300 Manual De Utilización

Ocultar thumbs Ver también para Safe House PG300:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
1. COM/NC ports
2. GND
3. Wired zone 3+GND
4. Wired zone 2+GND
5. Wired zone 1+GND
Wired zones notes
1. The voltage for the wired detectors should be no more than 5V. The passive signal line
is the best choice.
2. Please connect the wire being off the power to avoid the short circuit and burning the
host.
3. All the wired defense zones could be "normally close" or" normally open". The users
can connect the wire according the wireless detectors or as own requirement.
4. Attributes setting of APP wireless defense zones: the wired zone 1 is corresponded to
the defense zone 97 of APP, the wired zone 2 is corresponded to the defense zone 98,
wired zone 3 is corresponded to the defense zone 99.
System start-up
1. Insert the 2G compatible SIM card, without PIN CODE
2. Connect the indoor siren
3. Connect the 220V power to a wall socket then to the main unit power input
4. Turn ON the back-up battery
Note: If you insert the SIM card after turning on the main unit you could damage the
unit or not receive the GSM signal. Check if the GSM signal LED flashes. Restart
system and check if SIM card is 2G compatible and has PIN Code deactivated.
1
2 3 4 5
6
7
8
6. Battery ON/OFF button
7. Set button
8. Siren output
9. Power input
10. GSM
card slot
14
14
9
EN
10