Double Insulation; Extension Cables - BLACK&DECKER KG65 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
ENGLISH
• Check mounting flanges and the disc are correctly
fitted and are undamaged.
• Ensure you are using the correct size and type of
disc for the task.
• Ensure the disc, wire brush and sanding
accessories are rated in excess of the spindle rpm
of your angle grinder. Allow a newly assembled
wheel to idle off-load for 30 seconds before starting
any operation.
Save these instructions!

DOUBLE INSULATION

Your tool is double insulated. This means that all
the external metal parts are electrically insulated
from the mains power supply. This is done by
placing insulation barriers between the
electrical and mechanical components making it
unnecessary for the tool to be earthed. Note:
Double insulation does not take the place of
normal safety precautions when operating this
tool. The insulation system is for added protection
against injury resulting from a possible electrical
insulation failure within the tool.
ELECTRICAL SAFETY
Be sure your supply is the same as the voltage given
on the rating plate. This tool is fitted with a two-core
cord and plug.
MAINS PLUG REPLACEMENT (UK ONLY)
Should the mains plug need replacing and you are
competent to do this, proceed as instructed below.
If you are in doubt, contact a Black & Decker service
repair agent or a qualified electrician.
• Disconnect the plug from the power supply.
• Cut off the plug and dispose of safely. A plug with
bared copper conductors is very dangerous if
engaged in a live socket outlet.
• Only fit BS1363A approved plugs fitted with the
correctly rated fuse. Note: Fuses do not give
personal protection against electric shock.
• The cable wire colours, or a letter, will be marked at
the connection point of most good quality plugs.
Attach the wires to their respective points in the
plug (see diagram). Brown = L (live), blue = N (neutral).
• Before replacing the top cover of the plug ensure
that the cable restraint is holding the outer sheath of
the cable firmly and that the two leads are correctly
fixed at the terminal screws.
• Your product is supplied with a non-rewireable plug,
if the fuse cover is missing or damaged do not use
the plug.
20
Fit a plug
approved
to BS1363A
N
Connect
blue to
N (neutral)
Make sure that
the outer sheath
of the cable is held
firmly by the clamp
Warning! Never connect live or neutral wires to the
earth pin marked E or
Australia and New Zealand only
Should the mains pug or cordset of this equipment be
damaged it must only be replaced by an authorised
Black & Decker service agent as special purpose tools
are required.

EXTENSION CABLES

You can use up to 30m (100ft) of Black & Decker 2-core
extension cable (or 3-core extension cable in Australia
and New Zealand) without undue loss of power.
Note: An extension cable should not be used unless
absolutely necessary. Use of an improper extension
cable could result in a risk of fire and electric shock.
If an extension cable must be used, make sure it is
properly wired and in good electrical condition.
UNWANTED TOOLS AND THE ENVIRONMENT
Should you find one day that the tool needs
replacement or is of no further use, think of the
protection of the environment. Black & Decker
service agents will accept old tools and will
dispose of them in an environmentally safe way.
THE BLACK & DECKER GUARANTEE (UK, AUSTRALIA
AND NEW ZEALAND ONLY)
If your Black & Decker product becomes defective due
to faulty materials and workmanship, within 24 months
from the date of purchase, we guarantee to either
replace all defective parts or at our discretion, replace
the unit free of charge provided that:
• The product is returned to us or our authorised
repairers with evidence of date of purchase.
• The product has not been used for trade,
professional or hire purposes.
Fit a 5 amp fuse
E
approved to
BS1362
L
Connect
brown to
L (live)
Never use
a light socket
.
Tabla de contenido
loading

Este manual también es adecuado para:

Kg72Kg90

Tabla de contenido