Commissioning
2
Mounting
Installation via holes for M4-sized screws in the case or via a mounting system
(accessory).
A Turning connector, turnable 90°
B Indicator diodes:B1 - Status LED, B2 - Decode LED
C Laser beam
D Optical axis
NOTE
Degree of protection IP 67 is only achieved with screwed-on connector!
3
Electrical connection – Commissioning with factory settings
Connect 5VDC voltage supply and, if necessary, switching input and RS 232
interface.
Start Leuze BCL Config terminal program on terminal/PC.
Activate the BCL 8 Terminal function in the BCLconfig program.
Switch on supply voltage; the status LED must illuminate green.
Activate scanner via switching input or RS 232 command "+". The laser switches
itself on.
Hold the following "LEUZE" sample bar code up to the BCL 8 at a distance of
approx. 70 ... 80mm.
With a successful reading the laser beam is switched off and the result is shown
on the screen.
Close reading gate by deactivation of the switching input or the RS 232 com-
mand "-".
LEUZE
EN