4-17. Timer/Cycle Counter
1
1
Amperage Control
2
Output Control (Contactor)
To read timer/cycle counter, hold Amper-
age and Output (contactor) buttons while
turning on power. When machine first
powers up, the displays will show the
OM-363 Page 44
2
(CE Nameplate)
1
2
software number and revision for the first
seven seconds. It will then show arc time
and cycle count.
3
Timer Display
The hours and minutes are displayed on
the volt and amp meters for the first five
1 2 3
4 5 6
1 2 3
4 5 6
seconds, and are read as 1, 234 hours
and 56 minutes.
4
Cycle Display
The cycles are displayed on the volt and
amp meters for the next five seconds,
and are read as 123, 456 cycles.
3
4