4-18. Resetting Unit To Factory Default Settings (All Models)
1
Process Control
2
Amperage Control
3
Output Control
4
Start Control
1
2
3
4
(CE Nameplate)
1
2
4
3
5
Power Switch
To reset all welding power source functions
to original factory settings, turn power off.
Push and hold the Process, Amperage,
5
5
Output, and Start controls and turn On pow-
er. Hold switch pads for approximately 7
seconds (or until software version number
_ _ _ _ _ _-_clears meters).
OM-363 Page 45